Mr. Heater MH15 Скачать руководство пользователя страница 4

e4

general inFOrMatiOn

A.  The MH15 is a high pressure propane appliance and 

is designed to be operated from a 14.1 or 16.4 ounce 
disposable propane cylinder. (Propane cylinder not 
included.) Every unit is tested during manufacturing and 
shipped fully assembled except for the plastic stand.

b.  These heaters are equipped with automatic Safety  

Shutoff Valves. The gas flow will automatically stop if 
the heater fails to operate for any reason.

C.  Maximum safety and convenience have been built into 

the Hi-Med-Lo Control Valve/Regulator. The following 
table lists the approximate bTU’s consumed and the  
operating hours you can reasonably expect from   
disposable propane cylinders.

Valve  

 

position 

Btu input  cylinder 14.1 oz.  cylinder 16.4 oz.

Hi 

15,000 

1.3 hours 

 

1.5 hours

Med 

12,000 

1.6 hours 

 

1.8 hours

Lo 

10,000 

1.9 hours 

 

2.2 hours

Figure 3

Fuel gas OdOr

lp gas and natural gas have man-made odorants added 
specifically for detection of fuel gas leaks.
if a gas leak occurs you should be able to smell the fuel 
gas. since propane (lp) is heavier than air you should smell 
for the gas odor low to the floor. anY gas OdOr is YOur 
signal tO gO intO iMMediate actiOn!

  • Do not take any action that could ignite the fuel gas. Do not 

operate any electrical switches. Do not pull any power supply 
or extension cords. Do not light matches or any other source 
of flame. Do not use your telephone.

  • Get everyone out of the building and away from the area 

immediately.

  • Close all propane (LP) gas tank or cylinder fuel supply valves, 

or the main fuel supply valve located at the meter if you use 
natural gas.

  • Propane (LP) gas is heavier than air and may settle in low 

areas. When you have reason to suspect a propane leak, keep 
out of all low areas.

  • Use your neighbor’s phone and call your fuel gas supplier and 

your fire department. Do not re-enter the building or area.

  • Stay out of the building and away from the area until declared 

safe by the firefighters and your fuel gas supplier.

  • FINALLY, let the fuel gas service person and the firefighters 

check for escaped gas. Have them air out the building and 
area before you return. Properly trained service people must 
repair any leaks, check for further leakages, and then relight 
the appliance for you.

OdOr Fading - nO OdOr detected

 

• Some people cannot smell well. Some people cannot smell 

the odor of the man-made chemical added to propane (LP) or 
natural gas. You must determine if you can smell the odorant 
in these fuel gases.

  • Learn to recognize the odor of propane (LP) gas and natural 

gas. Local propane (LP) gas dealers will be more than happy 
to give you a scratch and sniff pamphlet. Use it to become 
familiar with the fuel gas odor.

  • Smoking can decrease your ability to smell. being around an 

odor for a period of time can affect your sensitivity to that 
particular odor. Odors present in animal confinement buildings 
can mask fuel gas odor.

 

• 

the odorant in propane (lp) gas and natural gas is 
colorless and the intensity of its odor can fade under 
some circumstances.

  • If there is an underground leak, the movement of gas through 

the soil can filter the odorant.

  • Propane (LP) gas odor may differ in intensity at different levels. 

Since Propane (LP) gas is heavier than air, there may be more 
odor at lower levels.

  • always be sensitive to the slightest gas odor. 

If you 

continue to detect any gas odor, no matter how small, treat 
it as a serious leak. Immediately go into action as discussed 
previously.

attentiOn - critical pOints tO 
reMeMBer! 

  • Propane (LP) gas has a distinctive odor. Learn to recognize 

these odors. (Reference Fuel Gas Odor and Odor Fading 
sections to the left and above).

  • Even if you are not property trained in the service and repair 

of the heater, ALWAYS be consciously aware of the odors of 
propane (LP) gas and natural gas.

  • If you have not been properly trained in repair and service of 

propane (LP) gas then do not attempt to light heater, perform 
service or repairs, or make any adjustments to the heater on 
the propane (LP) gas fuel system.

  • A periodic sniff test around the heater or at the heater’s 

joints; i.e. hose, connections, etc., is a good safety practice 
under any conditions. If you smell even a small amount of gas, 
CONTACT YOUR FUEL GAS SUPPLIER IMMEDIATELY. DO NOT 
WAIT!

Содержание MH15

Страница 1: ...ctly a fire or explosion may result causing property damage personal injury or loss of life WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appli ance WHAT TO DO IF YOU SMELL GAS Do not try to light appliance Extinguish any open fla...

Страница 2: ...rbon monoxide a chemical known to the State of California to cause cancer and birth defects or other reproductive harm This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm CONTENTS Warnings 2 Assembly Information 2 Odor Fade Warning 3 General Information 4 Safe Operation 5 Ventilation 5 Minimum Clearance from Combustible Mate...

Страница 3: ...of proper ventilation air will lead to improper combustion Improper combustion can lead to carbon monoxide poisoning leading to serious injury or death Symptoms of carbon monoxide poisoning can include headache dizziness and difficulty in breathing GENERAL INFORMATION A The MH15 is a high pressure propane appliance and is designed to be operated from a 14 1 or 16 4 ounce disposable propane cylinde...

Страница 4: ...on and the firefighters check for escaped gas Have them air out the building and area before you return Properly trained service people must repair any leaks check for further leakages and then relight the appliance for you ODOR FADING NO ODOR DETECTED Some people cannot smell well Some people cannot smell the odor of the man made chemical added to propane LP or natural gas You must determine if y...

Страница 5: ... position or for any other reason DO NOT ATTEMPT TO REPAIR OR TAMPER with the heater Any tampering could make the use of the heater unsafe and dangerous Return the heater to the dealer or the address given on the last page for repair or replacement J FOR STORAGE The heater Hi Med Lo Off regulating valve should always be turned to off when the heater is not in use Allow at least 15 minutes for cool...

Страница 6: ...ht heater D If burner does not light within 30 seconds turn the heater s regulator knob to off clockwise and allow at least five minutes for gas to dissipate before attempting to relight E NOTE Should the orifice become clogged as indicated by low volume of gas when operating on Hi with a full cylinder or should the heater fail to operate properly for any reason return the heater to the dealer or ...

Страница 7: ... w Orifice Assembly 2 F237425 12 Thermocouple Lead 3 42110 Plenum Assembly Complete 4 F232138 Screen Assembly 5 42131 Replacement Regulator w Safety Shutoff 6 42135 Replacement Regulator Hi Med Lo Off 7 17413 Wire Guard 8 Reflector For Reference Only 9 75217 Plastic Stand 10 42141 Manifold Tube Figure 6 ALL WARRANTY CLAIMS REQUIRE PROOF OF PURCHASE 7 8 2 4 3 1 6 5 9 10 ...

Страница 8: ...iod and found by the Company to have imperfections in material or workmanship If a part is damaged or missing call our Technical Support Department at 800 251 0001 Address any Warranty Claims to the Service Department Mr Heater Inc 4560 W 160TH ST CLEVELAND OHIO 44135 Include your name address and telephone number and include details concerning the claim Also supply us with the purchase date and t...

Страница 9: ...osión que provocaría daños materiales lesiones o muertes ADVERTENCIA No almacene ni utilice gasolina ni ningún otro vapor ni líquido inflamable cerca de este ni de ningún otro artefacto Los cilindros LP que no están conectados al calentador no deben almacenarse cerca de este ni de ningún otro artefacto QUÉ HACER SI DETECTA OLOR A GAS No intente encender el artefacto Apague todas las llamas expuest...

Страница 10: ...o de california produce cáncer y defectos de nacimiento u otros daños reproductivos Este producto contiene sustancias químicas que de acuerdo con el estado de California producen cáncer defectos de nacimiento u otros daños reproductivos CONTENIDO Advertencias S 2 Información de armado S 2 Advertencia de disipación del olor S 3 Información general S 4 Seguridad en el uso S 5 Ventilación S 5 Distanc...

Страница 11: ...JE FUNCIONANDO MIENTRAS DUERME ADVERTENCIA DE DISIPACIÓN DEL OLOR ADVERTENCIA Peligro de asfixia No utilice este calentador para calentar locales habitados por personas No lo utilice en áreas sin ventilación No obstruya el flujo de aire necesario para la combustión y la ventilación Deberá suministrar la ventilación adecuada para garantizar que el calentador disponga del aire que necesita para la c...

Страница 12: ...servicio de gas y los bomberos revisen si hay fugas de gas Haga que ventilen el edificio y el área antes de su regreso Un agente de servicios calificado debe reparar cualquier fuga revisar si hay otras fugas y volver a encender el artefacto por usted DISIPACIÓN DEL OLOR NO SE DETECTA NINGÚN OLOR Algunas personas tienen problemas de olfato Algunos no pueden detectar el olor del químico artificial a...

Страница 13: ...ICACIÓN ALGUNA Cualquier modificación podría hacer que el uso del calentador se torne riesgoso o peligroso Retorne el calentador al distribuidor o a la dirección que aparece en la última página para su reparación o para cambiarlo por otro J ALMACENAMIENTO La válvula de regulación Hi Med Lo Off Alto Medio Bajo Apagado del calentador siempre debe encontrarse en la posición de Off cuando no lo esté u...

Страница 14: ...o se enciende dentro de los 30 segundos mueva el botón del regulador del calentador a la posición de Off en sentido horario y deje disipar el gas durante al menos 5 minutos antes de volver intentar encenderlo E NOTA Si se atascara el orificio lo que podría notar si hay un bajo volumen de gas mientras el equipo funciona en Hi Alto con un cilindro lleno o si el calentador dejara de funcionar correct...

Страница 15: ...ridad con orificio 2 F237425 Cable de termocupla de 30 cm 12 3 42110 Cámara de aire completa 4 F232138 Conjunto de la rejilla 5 42131 Regulador de reemplazo con válvula de seguridad 6 42135 Reemplazo para regulador Hi Med Lo Off 7 17413 Cubierta de alambre 8 Reflector sólo para referencia 9 75217 Base de plástico 10 42141 Tubo del colector Figura 6 PARA TODA RECLAMACIÓN DE GARANTÍA DEBERÁ PRESENTA...

Страница 16: ...e un año y que la Compañía determine que presentan imperfecciones materiales o de fabricación Si alguna de las partes está dañada o si le falta alguna llame a nuestro Departamento de Asistencia Técnica al 800 251 0001 Dirija sus reclamos de garantía a Service Department Mr Heater Inc 4560 W 160TH ST CLEVELAND OHIO 44135 Incluya su nombre dirección y número telefónico en su comunicación e incluya l...

Отзывы: