HDA SERIES WALK-BEHIND TROWEL • OPERATION MANUAL — REV. #0 (12/1/17) — PAGE 37
2. Wipe the Zerk grease fitting clean to prevent abrasive
material from entering the fitting during lubrication.
3. Lubricate the Zerk grease fitting with 1–1½ shots
of multipurpose grade grease.
DO NOT overgrease.
Replace the Zerk fitting cap when finished.
4. Repeat steps 1–3 for the remaining grease fittings on
the spider assembly.
Blade Pitch Adjustment
Perform maintenance adjustment of blade pitch using a
bolt on the trowel arm lever (Figure 57). This bolt is the
contact point of the trowel arm with the lower wear plate
on the thrust collar. The goal of adjustment is consistent
blade pitch and finishing quality.
Figure 57. Blade Pitch Adjustment Bolt
Look for the following indications when determining if blade
pitch adjustment is necessary:
Are blades wearing out unevenly (i.e. one blade is
completely worn out while the others look new)?
Does the machine have a perceptible rolling or bouncing
motion while in use?
Does the guard ring rock up and down relative to the
ground while the machine is in use?
SPIDER
PLATE
BLADE PITCH
ADJUSTMENT
BOLT
TROWEL
ARM
TROWEL ARM
LEVER
TROWEL
BLADE
MAINTENANCE
Once it has been determined that blade pitch adjustment
is necessary, do the following:
1. Place the trowel on a flat, level surface, with blocks
under the main guard ring for support. Any uneven
spots in the floor or debris under the trowel blades
will cause an incorrect perception of adjustment. A
5 ft. x 5 ft. (1.5 m x 1.5 m), 3/4-inch-thick,
flat steel
plate is ideal.
2. Pitch the blades as flat as possible (Figure 58). The
pitch adjustment bolts should barely contact the
lower wear plate (0.1-inch maximum clearance). All
adjustment bolts should be spaced the same distance
from the lower wear plate. If any one of the bolts does
not make contact, adjustment is necessary.
Figure 58. Blades Pitched Flat (Correct)
3. Adjust the “high” bolts down to the level of the bolt
that is not touching, or adjust the “low” bolt up to the
level of the higher ones. Whenever possible, adjust the
“low” bolt up to the level of the rest of the bolts. This is
the fastest method, but it may not always work. After
adjustment, verify that the blades pitch correctly.
4. If the trowel still finishes poorly after blade pitch
adjustment has been performed, blades, trowel arms,
and trowel arm bushings should be inspected for
improper adjustment, wear, or damage.
GEARBOX
BLADE
TROWEL
ARM MOUNTING
BAR
LOWER
WEAR PLATE
PITCH
ADJUSTMENT
BOLT
STEEL TEST
SURFACE
NOTICE
Incorrectly adjusted blades will often be unable to pitch
flat. This can occur if the adjustment bolts are raised
too high. Conversely, adjustment bolts that are too low
will prevent the blades from being pitched high enough