background image

 

 
ATTENTION: the check valve installed in the pump outlet and in the Brio 2000 
inlet can cause some anomalies during the normal working of Brio 2000. 
Therefore it’s advisable avoiding its installation between the pump and Brio 
2000. 
 
4. 

Attention:

 

To modify the operating pressure adjustment it is necessary to take the 
cover away. Skilful people only must handle that operation, taking care 
of the electric-shock risks. 
Such pressure adjustment modifies the starting pressure limit of the 
pump. The exit pressure of device never increases. The pressure 
difference between the operating pressure value – set on the device – 
and the maximum pressure of the pumps must be higher than 0,6 bar. 

When it is necessary to modify the adjustment: 

1_When the higher top is situated at more than 15 mt higher of the 
device (max water column: 30 mt). 
2_For the applications of the pump in load, that is when the loading 
pressure is added up to the pressure of the pump, max. 10 bar. 

 
 
 
 

BRIO 2000 UNICO 72PAG.  6-03-2007  11:50  Pagina 14

Regulateurs-pression-BRIO-200M-mpvnotice.pdf/mai15

www.motor-pump-ventilation.com

Содержание BRIO 2000M

Страница 1: ...Owner s manual ELECTRONIC PRESSURE CONTROL FOR SINGLEPHASE PUMP Type BRIO 2000M Regulateurs pression BRIO 200M mpvnotice pdf mai15 www motor pump ventilation com ...

Страница 2: ...nut 2 Dry stop indicator 7 Line connection 3 Voltage indicator 8 1 male threaded connection inlet By request 1 female revolving nut 4 Motor connection 9 Pressure gauge Brio2000 M and 2000 MT versions only 5 Operating pressure setting screw Regulateurs pression BRIO 200M mpvnotice pdf mai15 www motor pump ventilation com ...

Страница 3: ...re it verifies any possible presence of water leakages in the very system 2 SAFETY REGULATIONS To avoid shocks and fire risks read and follow closely the following instructions Always unplug the device from the mains before carrying out any work on it Be sure that the electric line connecting the device to the mains and the extension leads have a cross section suitable for pump power and be sure t...

Страница 4: ... are pointing to the same direction as the fluid flowing through the pipe Check perfect water tightness of all water connections If you are using a pump with a pressure higher than 10 bar install a pressure reducer on the Brio 2000 s inlet 2 For the electrical connection of the version supplied without electric leads follow the wiring diagram on the printed circuit board cover or on the drawing fo...

Страница 5: ...ch pressure adjustment modifies the starting pressure limit of the pump The exit pressure of device never increases The pressure difference between the operating pressure value set on the device and the maximum pressure of the pumps must be higher than 0 6 bar When it is necessary to modify the adjustment 1_When the higher top is situated at more than 15 mt higher of the device max water column 30...

Страница 6: ...220Vac 110Vac Regulateurs pression BRIO 200M mpvnotice pdf mai15 www motor pump ventilation com ...

Страница 7: ... the pump by connecting the Brio 2000 power plug to a current outlet when the pump stops open the tap situated higher up 2 Installation is correct if the flow from the tap is regular and if the pump works continuously If there is no water you can try to make the pump work without interruption for a period of time longer than the device s working time by keeping the RESET button depressed If the pr...

Страница 8: ...Regulateurs pression BRIO 200M mpvnotice pdf mai15 www motor pump ventilation com ...

Страница 9: ...Regulateurs pression BRIO 200M mpvnotice pdf mai15 www motor pump ventilation com ...

Страница 10: ...SPARE PARTS Regulateurs pression BRIO 200M mpvnotice pdf mai15 www motor pump ventilation com ...