User Guide
HR1203 Evaluation Kit (EVKT-1203)
HR1203 Evaluation Kit User Guide Rev 1.0
MonolithicPower.com
15
5/7/2019
MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2019 MPS. All Rights Reserved.
Click
“Debug” again to turn off the real-time programming function. The color of the button should
return to gray.
⚠️
Real-time programming is a risky programming mode. If you make a change in a
data box and click
“Enter,” then all panel parameters, not only the changed one, will be
programmed to the chip. Therefore it is strongly recommended to repeatedly confirm panel
parameters before clicking
“Enter.”
⚠️
Do not forget to click
“Enter” in real-time programming. Otherwise, the data
change in GUI will not be updated to the chip.
5. Close the GUI. Since the panel parameters restore default values every time restarting the GUI, it is
better to save current panel parameters before exiting.
6. If in online mode, disconnect AC input then reset the communication interface and EVB
(1)
.
If in offline mode, reset the communication interface and EVB
(1)
.
Note:
1)
To reset communication interface:
Ensure that the VCC of the communication interface is fully discharged.
To reset EVB:
For offline mode, ensure that the EBV VCC is fully discharged. For online mode, ensure that the EVB VCC is fully
discharged and the bus bulk capacitor is discharged below 10V.
VCC fully discharged:
VCC discharged below 2V. The discharge time may vary with different application designs.