User Guide
HR1203 Evaluation Kit (EVKT-1203)
HR1203 Evaluation Kit User Guide Rev 1.0
MonolithicPower.com
12
5/7/2019
MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2019 MPS. All Rights Reserved.
Figure 15: Design-VOUT Panel
E. Design-PF COMP Panel
This panel configures the PF compensation parameters, which can improve the PF of the PFC
stage. Compensation can be controlled in different degrees according to different input ranges
(see Figure 16).
Figure 16: Design-PF COMP Panel
F. Design-Loop Panel
This panel can determine the load point to enter burst mode by configuring Burst Mode Load. Kp
and Ki of closed-loop control can also be set (see Figure 17).
If Set-Up Mode is set to
“Auto,” Kp and Ki are kept at their defaults.
If Set-Up Mode is set to
“Manual,” Kp and Ki can be changed. Related bode plots are drawn to
help check gain and phase margin of the loop.