Error Code

Code

E00

E02

E06

E07

E10

E13

E14

Error

No Error 

Battery 

Over-voltage 

Equipment 

Overheating 

Environment 

Over-temperature 

Solar 

Over-voltage 

Solar Reverse 

Polarity

Battery Reverse

Polarity 

Description

Battery voltage has 

exceeded controller 

limit. 

Controller exceeds 

operating temperature 

limit. 

The device working 

surrounding temperature 

is too high, and the 

controller would stop 

charging anytime. 

Solar array voltage exceeds 

controller rated input 

voltage.  

Solar array input wires 

connected with reverse 

polarity. 

Battery connection wires 

connected with reverse 

polarity. 

Quick Troubleshoot

-

Check battery bank voltage 

for compatibility with 

controller. 

Ensure the controller is placed 

in a well-ventilated cool, 

dry place. 

Try to lower the working 

surrounding temperature.

Decrease the voltage of solar 

panels connected to the 

controller.

Disconnect and re-connect 

with correct wire polarity.

Disconnect and re-connect 

with correct wire polarity

*Note: the missing error codes in the above chart indicates that this controller has no such 

error or alarm condition 

11

12

Содержание M2430C

Страница 1: ...M2430C MPPT Solar Charge Controller Flush Mount Negative Grounded User Manual We may modify these specifications without prior notice ...

Страница 2: ...stalling this device And please don t plug in any AC source to this DC DC product or it may cause a fire or burn to the device Connecting wires to this device can generate sparks please wear proper insulation gear while installing this device To avoid damage to the battery or controller use proper fuses in wiring Please do not hesitate to contact the professions if you need help with fuse sizing Th...

Страница 3: ...iple MPPT charge algorithms in combination to boost charging e ciency in di erent weather and temperature conditions Built in bu er allows max 25 exceeding rated power input Industrial grade design with full range of electronic protections like reverse polarity protection for solar panels and battery wiring Auto recognition of 12V 24V battery system voltage Lithium battery excluded from this featu...

Страница 4: ...ccording to the right consequences 3 Tighten the terminal screws as much as possible Installation Remarks Please make sure the battery wires would be connected first and then connect the PV wires For di erent installation conditions and requirements we may either fix the controller first then connect the wires or we also may connect the wires first before we fix the controller If you need to re wiring ...

Страница 5: ...playing cycles through di erent views page by page as following pictures with temperature unit Celsius C by default 8 3 Displaying Cycle Information 4 LED indicators are placed underneath the below four touch screen operation keys Screen Status Not in Sleep Mode In Sleep Mode System Error Solar Input Not in Charging Charging Battery SOC 50 Charging Battery SOC 75 Charging Battery SOC 75 Indicator ...

Страница 6: ...e without saving the setting value 10 Setting Parameters 10 1 Battery Type Setting Battery Type Battery Description Lead acid Battery Sealed Battery SLD AGM Gel Battery Lithium Battery Advanced User Mode For professions only Description Parameters set on default not adjustable Battery system voltage automatically recognized Battery system voltage and parameter settings are only allowed to set by A...

Страница 7: ...d stop charging anytime Solar array voltage exceeds controller rated input voltage Solar array input wires connected with reverse polarity Battery connection wires connected with reverse polarity Quick Troubleshoot Check battery bank voltage for compatibility with controller Ensure the controller is placed in a well ventilated cool dry place Try to lower the working surrounding temperature Decreas...

Страница 8: ...pensation 12V 24V Auto FLD GEL SLD Manual Li User 12ma 12V 10ma 24V 100Voc 30A 3000 meters 450W 12V 900W 24V 250 180 50mm Value Battery Parameters Accessory List Package Status Yes Optional Yes Yes External Temperature Sensor Remote LCD Meter Bluetooth Module Parallel Charge Use Cable Installation Guidance Paper User Manual Optional Yes Inbuit System Wiring Grounded Negative Grounded RS485 Bluetoo...