![MPP Solar HYBRID LV 6048 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/mpp-solar/hybrid-lv-6048/hybrid-lv-6048_user-manual_1843971017.webp)
15
02
Maximum charging
current: To configure the
total charging current for
solar and utility chargers.
(Max. charging current =
utility charging c
solar charging current)
40A
50A
60A (default)
70A
80A
90A
100A
110A
120A
130A
140A
150A
160A
170A
180A
190A
200A
210A
220A
03
AC input voltage range
Appliances (default)
If selected, acceptable AC input
voltage range will be within
90-280VAC.
UPS
If selected, acceptable AC input
voltage range will be within
170-280VAC.
05
Battery type
AGM (default)
Flooded
Содержание HYBRID LV 6048
Страница 1: ...HYBRID LV 6048 INVERTER CHARGER Version 1 0 User Manual...
Страница 36: ...34...