COMMON
RINSE
DETERGENT
INSTALLATION
9
INSTALLATION (Cont.)
Chemical Connections
NOTE:
Consult a qualified chemical supplier
for your chemical needs.
Refer to Fig. 8
1. A chemical signal terminal block is
supplied for chemical dispensing
equipment.
2. The terminal block is located below
the control panel fuse block.
Refer to Fig. 9
3. The detergent signal is limited
to a maximum load of 1 Amp.
Signal voltage is 115VAC.
4. The Rinse aid/Sanitizer
signal is limited to a max-
imum load of 1 Amp.
Signal voltage is 115VAC.
Rinse aid/Sanitizer
Signal Connection Point
1 Amp Max load/115VAC
Figure 8
Chemical Dispenser
Signal
Terminal Block
Figure 9
Chemical Signal
Connection Points
Common Return
Detergent Signal Connection Point
1 Amp Max Load/115VAC