![Moyer Diebel MD2000-VHR Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/moyer-diebel/md2000-vhr/md2000-vhr_installation-operation-and-parts-manual_1842818019.webp)
Converting 3-Phase to 1-Phase Operation
Fig. 11
Installation
1. A vent fan control signal is provided on a terminal
block located inside the top-mounted control cabinet.
The terminal locations are clearly marked.
2. The 120VAC signal is designed only to operate an
external vent fan contactor (supplied by others) and is
limited to 0.5 AMP maximum load and is available
when the dishwasher power switch is turned ON.
DO NOT CONNECT A VENT FAN MOTOR TO THE
VENT FAN TERMINALS (FIG 11).
Chemical dispensing system connections
are provided.
Vent Fan Control Connection
Chemical Dispenser Connections
NOTE:
A commercial grade non-chlorinated
detergent is recommended.
1.
Detergent and rinse-aid 120VAC, Max.
1 Amp load control signals are located
inside the top-mounted control cabinet.
Connection points are located on the
terminal block (Fig. 11).
2.
The rinse-aid connection is 1/8" NPT
fitting located at the rear of the
machine (Fig. 12).
3.
Two 7/8" holes are provided on the
wash tank rear for detergent injection
and sensor.
Rinse-aid
Fig. 12
Fig. 13
Detergent
Injection
Detergent sensor
11
Содержание MD2000-VHR
Страница 32: ...12 11 10 14 13 9 8 7 6 5 4 1 2 3 Wash Pump Motor 24...
Страница 38: ...Door Lock 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 30...
Страница 48: ...5 6 7 9 3 4 1 2 8 11 10 Tracks 40...
Страница 50: ...Dish Racks 2 1 42...
Страница 51: ...Dish Racks 1 101273 DISH RACK FLAT BOTTOM A R 2 101285 DISH RACK PEG A R 43 Item Part Description Qty No No...
Страница 52: ...Electrical Schematic 44...
Страница 54: ...Blank Page This Page Intentionally Left Blank 46...