Installation
• To manually operate the new valve, four 2.5mm socket
allen screws must be removed, the valve coil removed,
and the valve globe rotated with pliers.
• The valve coil has an indicator
line showing valve position.
Ensure valve is reassembled in
the same position.
Remove four 2.5mm coil retaining allen
screws.
Remove the coil from the valve body.
Using pliers, turn the valve body key to
the vertical position to open valve.
Reassemble in reverse order.
1
2
3
Drain Valve Manual Operation
Fig. 7
7