Panel Layout of the WAC-1001 Series 

 

 

1.

 

Grounding screw 

2.

 

Terminal block for PWR1, PWR2, 
relay, DI1, and DI2 

3.

 

Reset button 

4.

 

System LEDs: PWR1, PWR2, PoE, 
FAULT, and STATE LEDs 

5.

 

RS-232 console port 

6.

 

10/100/1000BaseT(X) RJ45 Port 

7.

 

10/100/1000M LED 

8.

 

Model name 

9.

 

Screw hole for wall mounting kit 

10.

 

DIN-Rail mounting kit 

Содержание WAC-1001 Series

Страница 1: ...P N 1802010010014 1802010010014 WAC 1001 Series Quick Installation Guide Version 4 1 January 2021 Technical Support Contact Information www moxa com support 2021 Moxa Inc All rights reserved...

Страница 2: ...r damaged please contact your customer service representative WAC 1001 series wireless controller 1 cable holder with 1 screw 2 protective caps Wall mount kit Quick installation guide printed Warranty...

Страница 3: ...2 Terminal block for PWR1 PWR2 relay DI1 and DI2 3 Reset button 4 System LEDs PWR1 PWR2 PoE FAULT and STATE LEDs 5 RS 232 console port 6 10 100 1000BaseT X RJ45 Port 7 10 100 1000M LED 8 Model name 9...

Страница 4: ...ed to reattach the DIN Rail attachment plate to the WAC 1001 make sure the stiff metal spring is situated towards the top as shown in the figures below How to Mount the WAC 1001 STEP 1 Insert the top...

Страница 5: ...0 mm in diameter and the shafts should be less than 3 5 mm in diameter as shown on the right Do not screw the screws in all the way leave a space of about 2 mm to allow room for sliding the wall moun...

Страница 6: ...and power wiring in the same wire conduit To avoid interference wires with different signal characteristics should be routed separately You can use the type of signal transmitted through a wire to det...

Страница 7: ...The WAC 1001 has one relay output which consists of two contacts of the terminal block on the WAC 1001 s top panel Refer to the previous section for detailed instructions on how to connect the wires...

Страница 8: ...e and wall Pin Assignments 1000BaseT Ethernet Port Connection 1000BaseT data is transmitted on differential TRD signal pairs over copper wires MDI MDI X Port Pinouts Pin Signal 1 TRD 0 2 TRD 0 3 TRD 1...

Страница 9: ...Panel LEDs The WAC 1001 s front panel has seven LED indicators refer to the following table for details LED Color State Description Front Panel LED Indicators System PWR1 Green On Power is being supp...

Страница 10: ...ax input current 8 mA Console RS 232 RJ45 type LAN Port 10 100 1000BaseT X auto negotiation speed LED Indicators PWR1 PWR2 PoE FAULT STATE Power Requirements Input Voltage 12 to 48 VDC redundant dual...

Страница 11: ...mobile device and should be located at least 20 cm away from the human body The WAC 1001 is NOT designed for use by the general public A well trained technician is required to safely deploy the WAC 1...

Отзывы: