![Moxa Technologies ToughNet TN-5524-8PoE Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/moxa-technologies/toughnet-tn-5524-8poe/toughnet-tn-5524-8poe_quick-installation-manual_1842456007.webp)
- 7 -
Grounding the ToughNet Switch
Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI). Run the ground connection from the
grounding screw to the grounding surface prior to connecting devices.
ATTENTION
This product is intended to be mounted to a well-grounded
mounting surface such as a metal panel.
Connecting the Power Supplies
The ToughNet TN-5524-8PoE series switches support one power supply.
The M23 6-pin male connector on the TN-5524-8PoEfront panel is used
for the power input.
Pinouts for the power input port on the TN-5524-8PoE
Pinouts for the power input port on the TN-5524-8PoE
Pin
Description
Usage
1 PWR1 Live / DC +
Connect “PWR1 Live / DC +” to the Live
terminal when using an AC power source or
to the positive (+) terminal when using a DC
power source.
2 PWR1 Neutral / DC -
Connect “PWR1 Neutral / DC –” to the
Neutral terminal when using an AC power
source or to the negative (-) terminal when
using a DC power source.
3 Chassis Ground
Connect the “Chassis Ground” to the safety
ground terminal for AC inputs or to the
equipment ground bus for DC inputs.
STEP 1:
Plug your power cord connector to the power input port of the
TN-5524-8PoE switch.
STEP 2:
Screw the nut on your power cord connector to the power input connector
on the switch to ensure a tight connection.