ThinkCore V481 WinCE User’s Manual
Getting Started
2-7
System Time and Time Zone
Setting the System Time Manually:
Use the
date
, and
time
commands to query the current
system date/time or to set a new system date/time. The system time is save in RTC. Stopping the
system won’t affect the system time.
\> date
The current date is: Tuesday, November 22, 2005
Enter the new date (mm-dd-[yy]yy): 12-23-05
\> date /T
Wednesday, November 23, 2005
\> time
The current time is: 5:27:17 PM
Enter the new time (hh:mm:ss): 16:02:00
\> time /T
4:02:04 PM
Setting the Time Zone:
Windows CE 5.0 supports Time Zone. You can use
[Control Panel]
Æ
[Date/Time]
to adjust your current Time Zone. It also supports
Daylight Date
and
Daylight
Time
.
Starting and Stopping Services
After booting up, the V481 computer runs several services continuously to serve requests from
users or other programs. Notable services include telnet (“TEL0:”), World Wide Web HTTP
(“HTP0:”), and file transfer FTP (“FTP0:”). Most users will not use these services. However, you
can start or stop a service by using the “services” command. For example,
Start the FTP service by typing
\> services start FTP0:
Stop the FTP service by typing
\> services stop FTP0:
The default services in the V481 are:
TEL0: Telnet
Service
FTP0: FTP
Service
CON0: Console
Service
Troubleshooting Network Connectivity
The ipconfig tool prints the TCP/IP-related configuration data of a host, including the IP addresses,
gateway, and DNS servers.
\> ipconfig /all
Windows IP configuration
Ethernet adapter Local Area Connection:
IP Address: 192.168.4.127
Subnet Mask: 255.255.255.0
Adapter Name: PCI\E100CE1
Description: PCI\E100CE1
Adapter Index: 2