background image

 

DA-660-8/16-CE User’s Manual 

Fourth Edition, April 2008 

www.moxa.com/product

 

 

©

 2008 Moxa Inc., all rights reserved. 

Reproduction without permission is prohibited. 

 

Содержание ThinkCore DA-660-16-CE

Страница 1: ...DA 660 8 16 CE User s Manual Fourth Edition April 2008 www moxa com product 2008 Moxa Inc all rights reserved Reproduction without permission is prohibited...

Страница 2: ...ight to make improvements and or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and r...

Страница 3: ...60 Computer 2 2 Resetting Your DA 660 Computer 2 2 Operating Your DA 660 Computer Via Serial Console 2 2 Changing the Network Settings 2 2 Operating Your DA 660 Computer Via Telnet Client 2 3 User Gro...

Страница 4: ...h as HMI advertisement appliances and interactive panels The DA 660 WinCE series of ready to run embedded computers includes the 8 port DA 660 8 CE and the 16 port DA 660 16 CE The following topics ar...

Страница 5: ...Windows CE 5 0 operating system OS Using a common widely used programming environment makes DA 660 suitable for new system development and legacy system migration The hardware and software capabiliti...

Страница 6: ...to 140 F 5 to 95 RH Storage temperature 20 to 70 C 4 to 176 F 5 to 95 RH Regulatory Approvals EMC CE Class A FCC Class A Safety UL CUL TUV Warranty 5 years Software Features DA 660 ready to run embed...

Страница 7: ...1 including installable service providers for additional third party protocols and Media sense Networking and Communications Capabilities For network centric embedded application usage DA 660 not only...

Страница 8: ...g with subdirectories such as Windows Temp My Documents Network and Program Files Files can be temporarily stored in these directories but they will be deleted when the system is shut down or restarte...

Страница 9: ...sue For applications where important data is transmitted immediately and directly to a host you can store the necessary log data in RAM After the host receives the data the data does not need to be re...

Страница 10: ...be done via system commands after gaining access to the computer and others can be done by a Web based management system which is described in a later chapter The following topics are covered in this...

Страница 11: ...console utility of the target computer This method is particularly useful when using the computer for the first time After you have wired a serial cable go back to the development workstation and sta...

Страница 12: ...network ports situated in the same LAN as your development workstation Use a cross over Ethernet cable to connect your development workstation directly to the target computer or a straight through Eth...

Страница 13: ...d by default is the same as the user name useradd xxxx user xxxx has been added In addition you can permit this user to access a particular service by typing g followed by the user group name of the s...

Страница 14: ...ovember 23 2005 time The current time is 5 27 17 PM Enter the new time hh mm ss 16 02 00 time T 4 02 04 PM Adjusting RTC Time Use the command hwclock w to convert the system time to the RTC time hwclo...

Страница 15: ...me DA660CE Domain Name DNS Servers 192 168 1 6 NODETYPE 8 Routing Enabled NO Proxy Enabled NO To troubleshoot network connectivity reachability and name resolution use the ping command This command ve...

Страница 16: ...ies to SNMP agents and receives traps from SNMP agents The DA 660 computer installs an SNMP agent to serve as an SNMP device You should install the SNMP manager on the workstation computer for example...

Страница 17: ...ese computers control they often reside in harsh areas as the devices themselves and are away from system administrators To manage these computers operations such as networking server configuration fi...

Страница 18: ...e DA 660 CE To open the web based management system follow these steps 1 Point your PC s web browser to the DA 660 CE s IP address When the main page opens select Web Based Management 2 When prompted...

Страница 19: ...the corresponding text fields and then click Update to make the changes effective for the interfaces Serial Port Configuration The embedded computer has multiple high performance serial ports that can...

Страница 20: ...p 1 Click the Processes item on the main menu bar At the lower part of the page there is an area marked as Automatic Launching Step 2 Fill in the full path of the application in the first text field a...

Страница 21: ...n follow the instructions y To refresh the current directory click Current Directory at the top of the page In addition the management system offers a mechanism for file upload This mechanism helps yo...

Страница 22: ...6 CE as an example to demonstrate the steps you should follow to configure these parameters LCM Display Display the process values and parameters Up Key Browse sub menus upward Down Key Browse sub men...

Страница 23: ...t Console Port Press or use SEL to select an item Console Port Return Press or use SEL to select an item Network Settings Port eth0 for example Network Serial Port Press SEL eth0 eth1 Press SEL eth0 I...

Страница 24: ...e MOXA download center at http web4 moxa com support download_center asp to download the appropriate firmware update file for your embedded computer This will be an executable file such as DA660CE_V1...

Страница 25: ...al Firmware Upgrade Procedure 5 The upgrade proves should take about five minutes When the process is complete you will be asked if you wish to keep the current network settings Press Y to keep the cu...

Страница 26: ...DA 660 8 16 CE User s Manual Firmware Upgrade Procedure 6 Enter Y when prompted to reboot the embedded computer The system will be restarted with the new firmware in effect B 3...

Страница 27: ...p 1 Open Internet Explorer and point it the following IP address http 192 168 3 127 sysadmin Client IE4 If necessary log on as an administrator The default administrator user ID is admin and the defau...

Страница 28: ...rnal storage media such as USB drives and CompactFlash cards Q Where can I store files permanently on Moxa embedded computers A There is a sub directory named NORFlash under the root directory Use thi...

Страница 29: ...Yes Moxa embedded computers can be remotely rebooted Log onto the embedded computer from a remote client and use the command reboot to reboot the system Q What type of CompactFlash device is supported...

Страница 30: ...tions Step 2 In the first text field enter the full path of the application In the second text field enter any arguments if required Click Add Step 3 Repeat steps 1 and 2 to set up additional applicat...

Страница 31: ...How do I monitor processes on Moxa embedded computers A In the Telnet or serial console you can execute ps to monitor current processes In the web console there is a Processes page You can monitor pr...

Отзывы: