Auto Warning Settings
Event Settings
On the Event Settings page, you may configure how administrators are notified of certain system, network,
configuration, power, Din, and cellular module events. Depending on the event, different options for automatic
notification are available, as shown above.
refers to sending an e-mail to a specified address.
Trap
refers
to sending an SNMP Trap.
Dout
is available on the network, power, Din, and cellular module event.
SMS
refers
to sending a message to a specified phone number.
Cold start:
This refers to starting the system from a power off state, or after upgrading your firmware
Warm start:
This refers to restarting the OnCell G3100 without turning the power off.
Network Event:
These settings configure the OnCell to change the status of the relay output and SMS if the
specified connection goes down.
Console (web/text) login auth fail:
This field refers to a failed attempt to log in to a password protected
OnCell G3100 console.
IP changed:
With this IP address change, the OnCell G3100 will send an email or SMS warning after it reboots.
Password changed:
With this option selected, the OnCell G3100 will attempt to send an e-mail or SMS
warning after it reboots with a new console password. If the OnCell G3100 is unable to send an e-mail or SMS
message to the mail server within 15 seconds, it will still reboot without sending the e-mail or SMS.
Power event:
The OnCell G3100 provides two DC power inputs for redundancy. If either power fails, the
OnCell G3100 will attempt to send an e-mail warning, relay output, or SMS.
Din event:
When the status of digital input 1 or 2 is changed, the OnCell G3100 will attempt to send an e-mail,
trigger the digital output, or send an SMS.