Turbo Ring DIP Switch Settings 

 

The default setting for each DIP switch is OFF. The 
following table explains the effect of setting the DIP switch 
to the ON position. 

Turbo Ring Settings 

 

DIP 

DIP 1 

DIP 2 

DIP 3 

DIP 4 

 

– 

Ring Master  Ring Coupling 

port 

DIP 1, 2, 3 

 

ON 

– 

Enable 

Enable 

Activates 

Default  OFF 

– 

Disable 

Disable 

Disabled 

Turbo Ring V2 Settings 

 

DIP 

DIP 1 

DIP 2 

DIP 3 

DIP 4 

 

Ring Coupling  Ring Master 

Ring Coupling 
port 

DIP 1, 2, 3 

 

ON 

Backup port 
Enable 

Enable 

Enable 

Activates 

Default  OFF 

Primary port 
Enable 

Disable 

Disable 

Disabled. 

Software Installation Information 

For the NPort’s configuration, the default IP address of the NPort is: 
LAN: Static IP = 192.168.127.254; netmask = 255.255.255.0 
You may log in with the account name 

admin

 and password 

moxa

 to 

change any settings to meet your network topology (e.g., IP address) 
or serial device (e.g., serial parameters). You may also refer to Moxa 
support website 

https://www.moxa.com/support

 for user’s manual, 

driver, SNMP MIB, and NPort Search Utility. 

NOTE 

For NPort with DB Male serial ports, you may refer to the DB9 
Male Ports pin assignment section to loop back pin 2 and pin 3 
for the RS-232 interface to carry out a self test on the device. 

 

 

Pin Assignments and Cable Wiring 

DB9 Male Port Pinouts 

 

Pin 

RS-232 

RS-422/ 

RS-485-4w 

RS-485-2w 

DCD 

TxD-(A) 

– 

RxD 

TxD+(B) 

– 

TxD 

RxD+(B) 

Data+(B) 

DTR 

RxD-(A) 

Data-(A) 

GND 

GND 

GND 

DSR 

– 

– 

RTS 

– 

– 

CTS 

– 

– 

– 

– 

– 

 

 