NE-4100 Series User’s Manual
Serial Command Mode
9-7
OP Code Parameter
Comments
UB
xxx.xxx.xxx.xxx
(e.g., 192.168.1.1)
destination IP address 2, begin range
UC
xxx.xxx.xxx.xxx
(e.g., 192.168.1.1)
destination IP address 3, begin range
UD
xxx.xxx.xxx.xxx
(e.g., 192.168.1.1)
destination IP address 4, begin range
Ua
xxx.xxx.xxx.xxx
(e.g., 192.168.1.1)
destination IP address 1, end range
Ub
xxx.xxx.xxx.xxx
(e.g., 192.168.1.1)
destination IP address 2, end range
Uc
xxx.xxx.xxx.xxx
(e.g., 192.168.1.1)
destination IP address 3, end range
Ud
xxx.xxx.xxx.xxx
(e.g., 192.168.1.1)
destination IP address 4, end range
U1
0 – 65535
destination IP address 1, port
U2
0 – 65535
destination IP address 2, port
U3
0 – 65535
destination IP address 3, port
U4
0 – 65535
destination IP address 4, port
UX
0: no delimiter
1: enable 1-character delimiter
2: enable 2 character delimiter
number of characters to use as delimiter
UY
ASCII character in hex code
(i.e., “A1” for character 0xA1)
character to use for delimiter 1
UZ
ASCII character in hex code
(i.e., “A1” for character 0xA1)
character to use for delimiter 2
UF
0 – 65535 (ms)
force transmit time
Digital IO
OP Code Parameter
Comments
DM
bytes 1 and 2 (DIO #)
00: DIO 0
01: DIO 1
02: DIO 2
03: DIO 3
byte 3 (DIO mode)
0: input
1: output
set DIO mode
(e.g., “000” sets DIO 0 to input mode)
DS
bytes 1 and 2 (DIO #)
00: DIO 0
01: DIO 1
02: DIO 2
03: DIO 3
byte 3 (DIO status)
0: low
1: high
set DIO status
(e.g., “011” sets DIO 1 to high)
RSPSupply - 1-888-532-2706 - www.RSPSupply.com