1-2
Smartio
C168H/HS User’s Manual
Hardware Configuration Method
Smartio
Family
JP1
Traditional
Multipoort Board
Jumper
ON
1 2 3 4
Switch
.........
.........
New :
set I/O address
Traditional :
set switch and
and IRQ via software
and jumper manually for
Utility.
I/O address and IRQ.
Instead of using traditional jumper or switch for IRQ and I/O address settings,
hardware configuration of each port is easily set by DOS utility,
Io-irq.exe
, which
read and write the on-board EEPROM for configuration information through the
CAP
(
Configuration Access Port
)
address
. The CAP address is the only channel
via which the configuration utility Io-irq.exe can access the board, which is identical
to
the first port's base I/O address
.
The only jumper,
JP1
, is designed in case that users forget the CAP address.
Normally JP1 is left open. When JP1 is short, the CAP address is forced to a fixed
I/O address,
0xA700
. However, to adopt quick installation (described later), it is a
must to keep JP1 always short.
Quick Installation
To ease the hardware configuration, users who install
only one
Smartio
C168
Series board under Windows NT/95/98
are recommended to adopt
quick
installation
described in Chapter 2.
Because the family is so flexible in hardware configuration that they are compatible
virtually with all kinds of other manufacturer's multiport boards using 16450 or
16550 UART.