P/N: 1802045101010 

*1802045101010* 

ioThinx 4510 Series 

Quick Installation Guide 

 

Edition 1.0, August 2018 

Technical Support Contact Information 

www.moxa.com/support 

Moxa Americas: 
Toll-free: 1-888-669-2872 
Tel:  1-714-528-6777 
Fax:  1-714-528-6778 

Moxa China (Shanghai office): 
Toll-free: 800-820-5036 
Tel:  +86-21-5258-9955 
Fax:  +86-21-5258-5505 

Moxa Europe: 
Tel:  +49-89-3 70 03 99-0 
Fax:  +49-89-3 70 03 99-99 

Moxa Asia-Pacific: 
Tel:  +886-2-8919-1230 
Fax:  +886-2-8919-1231 

Moxa India: 
Tel:  +91-80-4172-9088 
Fax:  +91-80-4132-1045 

 

 

 

 

 

 

 2018 Moxa Inc. All rights reserved. 

 

 

Содержание ioThinx 4510 Series

Страница 1: ...a Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 Moxa India Tel 91 80 4172 9088 Fax 91 80 4132 1045 2018 Moxa Inc All rights reserved ...

Страница 2: ...ion applications Package Checklist 1 ioThinx 4510 product Quick installation guide printed 2 side cover plates Installation Connecting System Power Connect your 12 to 48 VDC power source to the terminal block SP and SP terminals on the ioThinx 4510 The ground connector of the system is on the back of the unit which will connect to the DIN rail when the product is attached to it ...

Страница 3: ... modules such as digital input and analog output modules Connecting the Field Power Ground Connect the Field Ground pin to the field power ground Connecting to the Network Ethernet Communication The ioThinx 4510 is equipped with dual unmanaged LAN ports RJ45 Connect a network Ethernet cable to either port to provide an Ethernet connection to the unit ...

Страница 4: ...XD DATA 1 3 RTS RXD DATA 2 4 CTS RXD DATA 2 5 GND GND GND 45M Module Wiring For detailed 45M module wiring refer to the ioThinx 4510 User Manual on the official website Installing the System on a DIN Rail Step 1 Hook the mounting clip of the unit onto the DIN rail and lower the clip onto the DIN rail Reserve at least 5 5 cm of space above the DIN rail to ensure that there is enough room to install...

Страница 5: ...le side by side with the head CPU module and then push the 45M module until it touches the DIN rail Next apply more force until the module clips to the DIN rail NOTE After the module is firmly attached to the DIN rail the module connections to the internal bus will be established Removing a 45M Module from a DIN Rail Step 1 Use your finger to lift the release tab on the lower part of the module ...

Страница 6: ... disconnected when removing the 45M module WARNING Be sure the power is off before removing modules to avoid unexpected damage Installing the Covers on the First and Last Module Attach the covers to the first and last module to cover the modules contacts NOTICE Be sure to attach the covers to provide electrostatic discharge protection ...

Страница 7: ...through the web console Default IP Address 192 168 127 254 Subnet Mask 255 255 255 0 NOTE Be sure to configure the host PC s IP address to use the same subnet as the unit For example 192 168 127 253 2 IOxpress Utility IOxpress is a utility that helps users with mass deployment of searching for and locating units on the local network This utility can be downloaded from Moxa s website 3 Loading the ...

Страница 8: ...del name in the search box or select a product from the drop down box and then click Search The ioLogik E1210 is used for the examples below Step 3 Go to the Software page to download the latest software for the product Specifications Input Current 800 mA 12 VDC Input Voltage 12 to 48 VDC Field Power 12 24 VDC Operating Temperature Standard Models 20 to 60 C 4 to 140 F Wide Temp Models 40 to 75 C ...