- 9 -
SC-Port Pinouts
SC-Port to SC-Port Cable Wiring
ST-Port Pinouts
ST-Port to ST-Port Cable Wiring
ATTENTION
This is a Class 1 Laser/LED product. Do not stare into the Laser
Beam.
Redundant Power Inputs
Both power inputs can be connected simultaneously to live DC power
sources. If one power source fails, the other live source acts as a backup,
and automatically supplies all of the Moxa Industrial Media Converter’s
power needs.
DIP Switch Setting
DIP No.
Function
ON
OFF
1
Auto Negotiation
Enable*
Disable
“ON”: Enables “Auto Negotiation” function, the speed and duplex states
for each port link segment are automatically configured using the
highest performance interoperation mode.
“OFF”: Disables “Auto Negotiation” function, the speed and duplex
states depend on the manual setting configuration.
2
Force TP Speed
100Mbps*
10Mbps
(Only when Auto Negotiation is disabled)
“ON”: Forces 100Mbps on Ethernet port.
“OFF”: Forces 10Mbps on Ethernet port.
3
Force TP Duplex
Full Duplex*
Half Duplex
(Only when Auto Negotiation is disabled)
“ON”: Forces Full Duplex on Ethernet port.
“OFF”: Forces Half Duplex on Ethernet port.