Dimensions; unit = mm (inch) 

 

DIN-Rail Mounting 

The aluminum DIN-rail attachment plate should be fixed to the back panel 
of the IMC-101G when you take it out of the box. If you need to reattach 
the DIN-rail attachment plate to the IMC-101G, make sure the stiff metal 
spring is situated towards the top, as shown in the figures below. 
STEP 1:   
Insert the top of the DIN rail into 
the slot just below the stiff metal 
spring. 

STEP 2:   
The DIN-rail attachment unit will 
snap into place as shown below. 

 

 

To remove the IMC-101G from the DIN rail, reverse steps 1 and 2 above. 
 

 

Содержание IMC-101G Series

Страница 1: ...om support Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89...

Страница 2: ...ensuring that your Ethernet equipment can withstand a variety of application environments such as hazardous locations Class 1 Division 2 Zone 2 IECEx and complies with CE FCC and UL Standards Package...

Страница 3: ...issipation vents 4 Dip switches 5 Power input PWR1 LED 6 Power input PWR2 LED 7 Fault LED 8 SFP port s 1000 Mpbs G2 LED 9 TP port s 1000 Mpbs G1 LED 10 1000BaseSFP fiber port 11 10 100 1000BaseT X por...

Страница 4: ...to reattach the DIN rail attachment plate to the IMC 101G make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 Insert the top of the DIN rail into the slo...

Страница 5: ...be less than 6 0 mm in diameter and the shafts should be less than 3 5 mm in diameter as shown in the figure on the right NOTE Test the screw head and shank size by inserting the screw into one of the...

Страница 6: ...hall be made either in the equipment or external to the equipment to provide the transient protection device to be set at a level not exceeding 140 of the peak rated voltage 6 Additional use guide The...

Страница 7: ...r electrical characteristics can be bundled together Keep input wiring and output wiring separate It is strongly advised that you label wiring to all devices in the system when necessary Grounding the...

Страница 8: ...ch is set to ON is not properly connected If neither of these two conditions is met the fault circuit will be closed Wiring the Redundant Power Inputs The top two contacts and the bottom two contacts...

Страница 9: ...connect to Ethernet enabled devices Below we show pinouts for both MDI NIC type ports and MDI X HUB switch type ports and also show cable wiring diagrams for straight through and crossover Ethernet c...

Страница 10: ...ther optical line is used to transmit data from device II to device I for full duplex transmission Remember to connect the Tx transmit port of device I to the Rx receive port of device II and the Rx r...

Страница 11: ...PORT ALARM DIP Switch is set to ON is not properly connected If neither of these two conditions occurs the fault circuit will be closed IMC 101G DIP Switch Setting NOTE To activate updated DIP switch...

Страница 12: ...TP port s 100 Mbps link is inactive Auto MDI MDI X Connection The Auto MDI MDI X function allows users to connect the IMC 101G s 10 100 1000BaseT X ports to any kind of Ethernet device without paying...

Страница 13: ...rt DIP Switches Port break alarm mask Link Fault Pass through SFP AN Force Alarm Contact One relay output with current carrying capacity of 1 A 24 VDC resistive Optical Fiber 1000BaseSX LSX LX LH LHX...

Страница 14: ...Protection Supported Mechanical Casing Metal IP30 protection Dimensions W x H x D 53 x 135 x 105 mm 2 1 x 5 3 x 4 1 in Weight 630 g Installation DIN rail or wall mounting optional kit Environmental L...

Отзывы: