LED Indicators 

The front panel of the IKS-G6524A/G6824A Series switch contains 
several LED indicators. The function of each LED is described in the 
following table. 

LED 

Color 

State  Description 

System LEDs 

STATE 

GREEN 

On 

The system has passed the 
self-diagnosis test on boot-up and is 
ready to run. 

Blinking 

1. System is undergoing the 
self-diagnosis test. 
2. Blinks continuously when pressing 
the reset button 5 seconds to reset to 
factory default. 
3. Blinks slowly when an ABC-02 
automatic backup device is detected. 

RED 

On 

The system failed self-diagnosis on 
boot-up. 

PWR1 

AMBER 

On 

Power is being supplied to the main 
module’s power input PWR1. 

Off 

Power is not being supplied to the 
main module’s power input PWR1. 

PWR2 

AMBER 

On 

Power is being supplied to the main 
module’s power input PWR2. 

Off 

Power is not being supplied to the 
main module’s power input PWR2. 

FAULT 

RED 

On 

The system has failed, or is under 
quick inspection. 

Off 

The system is operating normally. 

MSTR/ 

HEAD 

GREEN 

On 

The switch is set as the Master of the 
Turbo Ring, or as the Head of the 
Turbo Chain. 

Blinking 

The switch has become the Ring 
Master of the Turbo Ring, or the Head 
of the Turbo Chain, after the Turbo 
Ring or the Turbo Chain is down. 

Off 

The switch is not the Master of this 
Turbo Ring or is set as a Member of 
the Turbo   
Chain 

CPLR/TAIL 

GREEN 

On 

The switch’s coupling function is 
enabled to form a back-up path, or 
when it’s set as the Tail of the Turbo 
Chain. 

Blinking  Turbo Chain is down 

Off 

The switch disables the coupling 
function. 

When the system is importing/exporting data from or to an ABC-02 
automatic backup device, the FAULT, MSTR/HEAD, and CPLR/TAIL LEDs 
will blink in sequence. 
 
 
 

Содержание IKS-G6524A

Страница 1: ...xa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0...

Страница 2: ...d 4 protective caps for unused ports 2 rackmount ears Quick installation guide printed Warranty card Panel Layouts 1 Model Name 2 System status LEDs 3 10 100 1000BaseT X port status LEDs 4 100 1000Bas...

Страница 3: ...pply 1 PWR1 and Power Supply 2 PWR2 The connections for PWR1 and PWR2 are located on the rear side shown below Be sure to use a standard power cord with an IEC C13 connector which is compatible with t...

Страница 4: ...backup configurator to connect the IKS G6524A G6824A s USB storage port for configuration backup firmware upgrade or system log file backup USB Storage Port Type A Connector Pinouts Pin Description 1...

Страница 5: ...r is being supplied to the main module s power input PWR2 Off Power is not being supplied to the main module s power input PWR2 FAULT RED On The system has failed or is under quick inspection Off The...

Страница 6: ...E 802 3z for 1000BaseSX LX LHX ZX IEEE 802 3x for Flow Control IEEE 802 1D 2004 for Spanning Tree Protocol IEEE 802 1w for Rapid Spanning Tree Protocol IEEE 802 1s for Multiple Spanning Tree Protocol...

Страница 7: ...olarity Protection Present Physical Characteristics Housing IP 30 protection Dimensions 440 x 44 x 386 9 mm 17 32 x 1 73 x 15 23 in Installation 19 rack mounting Environmental Limits Operating Temp St...

Страница 8: ...nd the effect that overloading of the circuits might have on overcurrent protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this conce...

Страница 9: ...rth ground to adequately ground the chassis and protect the operator from electrical hazards To avoid risks of electric shock do not replace or remove the protective conductor 5 The IP rating is not p...

Отзывы: