background image

- 7 - 

 

WARNING 

Hot Surface. Do not touch. 

 

 

 

ATTENTION 

The SFP module only supports Laser Class 1 optical transceivers. 

 

Grounding the IEF-G9010-2MGSFP Series 

Grounding and wire routing help limit the effects of noise due to 
electromagnetic interference (EMI). Run the ground connection from the 
ground screw (M4 type) to the grounding surface prior to connecting 
devices. 

 

ATTENTION 

This product is intended to be mounted to a well-grounded 
mounting surface such as a metal panel. 

 

 

Wiring the Relay Contact 

The IEF-G9010-2MGFFP Series has one set of relay outputs. The relay 
uses two contacts on the terminal block of the IEF-G9010-2MGFFP Series 
front panel. Refer to the 

Wiring the Redundant Power Inputs

 section 

for instructions on how to connect the wires to the terminal block 
connector, and how to attach the terminal block connector to the terminal 
block receptor.   
The diagram below indicates the location of the relay contacts on the 
terminal block. 

 

Top View 

 

Right View 

Fault: 

The two contacts of the 

2-pin terminal block connector are 
used to detect user-configured 
events. The two wires attached to 
the fault contacts form an open 
circuit when a user-configured 
event 

is 

triggered. If a 

user-configured  event does not 
occur, the fault circuit remains 
closed. 

 

Wiring the Redundant Power Inputs 

The IEF-G9010-2MGSFP Series has two sets of power inputs—power 
input 1 and power input 2. The top and side views of the terminal block 
connector are shown below. 

Содержание EtherFire IEF-G9010-2MGSFP Series

Страница 1: ...090100012 1802090100012 IEF G9010 2MGSFP Series Quick Installation Guide EtherFire Family Version 2 1 February 2021 Technical Support Contact Information www moxa com support 2021 Moxa Inc All rights...

Страница 2: ...d Features Advanced Industrial Networking Capability MAC and IP address policy enforcement IPS IDS to monitor and prevent cyberthreats Virtual Patch mitigates the manual effort of having to patch devi...

Страница 3: ...k with latch for Power 2 input 9 Terminal block with latch for Power 1 input 10 Terminal block with latch for digital input 11 Terminal block with latch for relay output 12 Type C serial console port...

Страница 4: ...rail Mounting In the package the metal DIN rail mounting kit is fixed to the back panel of the IEF G9010 2MGSFP Series Mount the IEF G9010 2MGSFP Series on the corrosion free mounting rail that adhere...

Страница 5: ...r STEPS 2 3 Slightly pull the IEF G9010 2MGSFP Series forward and lift it up to remove it from the mounting rail Wall Mounting For some applications you will find it convenient to mount the IEF G9010...

Страница 6: ...t Be sure to disconnect the power cord before installing and or wiring your IEF G9010 2MGSFP Series Calculate the maximum possible current in each power wire and common wire Observe all electrical cod...

Страница 7: ...FP Series front panel Refer to the Wiring the Redundant Power Inputs section for instructions on how to connect the wires to the terminal block connector and how to attach the terminal block connector...

Страница 8: ...nd Tma 75 C min If you require further assistance please contact your Moxa representative Communication Connections Each IEF G9010 2MGSFP Series has three types of communication port 1 Type C console...

Страница 9: ...type ports and MDI X HUB Switch type ports 10 100Base T x RJ45 Pinouts MDI Port Pinouts MDI X Port Pinouts 8 pin RJ45 Pin Signal 1 Tx 2 Tx 3 Rx 6 Rx Pin Signal 1 Rx 2 Rx 3 Tx 6 Tx 1000BaseT RJ45 Pinou...

Страница 10: ...rd Console Off The IEF G9010 2MGSFP Series is NOT managed by Security Dashboard Console Blinking 1 When the MGMT LED is blinking every 1 second the IEF G9010 2MGSFP Series is rebooting the system 2 Wh...

Страница 11: ...A 12 V 0 605 A 24 V 0 308 A 48 V Input Voltage 12 24 48 VDC dual power input Power Consumption 15 18 W max Operating Temperature 10 to 60 C 14 to 140 F standard models 40 to 75 C 40 to 185 F wide temp...

Отзывы: