background image

 
 
 
 
 

Moxa EtherDevice™ Switch 

EDS-P506A-4PoE Series 

Hardware Installation Guide 

 
 
 
 
 
 
 
 
 
 

First Edition, July 2010 

 
 
 
 
 
 
 
 
 

 

©

 2010 Moxa Inc. All rights reserved. 

Reproduction without permission is prohibited. 

 
 
 

 

P/N: 1802005060010

Содержание EtherDevice EDS-P506-4PoE

Страница 1: ...Moxa EtherDevice Switch EDS P506A 4PoE Series Hardware Installation Guide First Edition July 2010 2010 Moxa Inc All rights reserved Reproduction without permission is prohibited P N 1802005060010...

Страница 2: ...d especially for security automation applications such as IP surveillance and gate of entry systems which can benefit from a scalable backbone construction and Power over Ethernet support The EDS P506...

Страница 3: ...ew 2 18 17 5 2 17 1 Grounding screw 2 Terminal block for power input PWR1 PWR2 and relay output 3 Heat dissipation orifices 4 Console port 5 DIP switches 6 Power input PWR1 LED 7 Power input PWR2 LED...

Страница 4: ...19 18 18 1 Grounding screw 2 Terminal block for power input PWR1 PWR2 and relay output 3 Heat dissipation orifices 4 Console port 5 DIP switches 6 Power input PWR1 LED 7 Power input PWR2 LED 8 Fault L...

Страница 5: ...Grounding screw 2 Terminal block for power input PWR1 PWR2 and relay output 3 Heat dissipation orifices 4 Console port 5 DIP switches 6 Power input PWR1 LED 7 Power input PWR2 LED 8 Fault LED 9 MSTR...

Страница 6: ...attachment plate should already be fixed to the back panel of the EDS P506A 4PoE when you take it out of the box If you need to reattach the DIN Rail attachment plate to the EDS P506A 4PoE make sure...

Страница 7: ...ess than 6 0 mm in diameter and the shafts should be less than 3 5 mm in diameter as shown in the figure to the right 6 0 mm 3 5 mm NOTE Before tightening the screws into the wall make sure the screw...

Страница 8: ...lculate the maximum possible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ra...

Страница 9: ...ts of relay contacts of the 6 pin terminal block connector are used to detect user configured events The two wires attached to the fault contacts form an open circuit when a user configured event is t...

Страница 10: ...itches The proprietary Turbo Ring protocol was developed by Moxa to provide better network reliability and faster recovery time Moxa Turbo Ring s recovery time is less than 300 ms Turbo Ring or 20 ms...

Страница 11: ...ctivates DIP switches 1 2 3 to configure Turbo Ring V2 settings OFF Enables the default Ring Coupling primary port OFF This EDS will not be the Ring Master OFF Do not use this EDS as a ring coupler OF...

Страница 12: ...g or the Turbo Chain is down Off When the EDS P506A 4PoE is not the Master of this Turbo Ring or is set as the Member of the Turbo Chain CPLR TAIL GREEN On When the EDS P506A 4PoE coupling function is...

Страница 13: ...into the port make sure the slider guide is positioned to the right side such that it fits snuggly into the port slider slider guide slider ridges slider slider guide slider ridges The 100 Mbps fiber...

Страница 14: ...put current 8 mA Optical Fiber Multi mode Single mode Wavelength 1300 nm 1310 nm Max Tx 10 dBm 0 dBm Min Tx 20 dBm 5 dBm Rx Sensitivity 32 dBm 34 dBm Link Budget 12 dB 29 dB Typical Distance 5 km a 4...

Страница 15: ...vel 3 EN61000 4 4 EFT Level 3 EN61000 4 5 Surge Level 3 EN61000 4 6 CS Level 3 EN61000 4 8 Shock IEC60068 2 27 Freefall IEC60068 2 32 Vibration IEC60068 2 6 WARRANTY 5 years Technical Support Contact...

Отзывы: