Multi mode: 

 

100BaseFX 

0 to 5 km, 1300 nm (50/125

μ

m, 800MHz*km) 

0 to 4 m, 1300 nm (62.5/125

μ

m, 500MHz*km) 

Single mode: 

 

100BaseFX 

0 to 40 km, 1310 nm (9/125

μ

m, 3.5 PS/(nm*km)) 

The concept behind the LC port and cable is quite straightforward. Suppose 
you are connecting devices I and II. Unlike electrical signals, optical signals do 
not require a circuit in order to transmit data. Consequently, one of the optical 
lines is used to transmit data from device I to device II, and the other optical 
line is used to transmit data from device II to device I, for full-duplex 
transmission. 

Remember to connect the Tx (transmit) port of device I to the Rx (receive) port 
of device II, and the Rx (receive) port of device I to the Tx (transmit) port of 
device II. If you make your own cable, we suggest labeling the two sides of the 
same line with the same letter (A-to-A and B-to-B, as shown below, or 
A1-to-A2 and B1-to-B2). 

 

LC-Port Pinouts

 

LC-Port to LC-Port Cable Wiring

 

Tx

Rx

 

A

B

Cable Wiring

 

 

                       A

 

 

                       B

A

B

 

 

 

ATTENTION 

This is a Class 1 Laser/LED product. To avoid causing serious 
damage to your eyes, do not stare directly into the Laser Beam. 

Turbo Ring DIP Switch Settings 

EDS-G509 series are plug-and-play managed redundant Ethernet switches. The 
proprietary Turbo Ring protocol was developed by Moxa to provide better 
network reliability and faster recovery time. Moxa Turbo Ring’s recovery time 
is less than 300 ms (

Turbo Ring

) or 20 ms (

Turbo Ring V2

) —compared to a 

3- to 5-minute recovery time for commercial switches—decreasing the possible 
loss caused by network failures in an industrial setting. 

There are 4 Hardware DIP Switches for Turbo Ring on the top panel of 
EDS-G509 that can help setup the Turbo Ring easily within seconds. If you do 
not want to use a hardware DIP switch to setup the Turbo Ring, you can use a 
web browser, telnet, or console to disable this function. 

NOTE

 

Please refer to the 

Turbo Ring DIP Switch

 section and 

Using 

Communication Redundancy

 section in the User’s Manual for 

more detail information about the settings and usage of 

Turbo Ring

 

and 

Turbo Ring V2

 

Содержание EtherDevice EDS-G509

Страница 1: ...rdware Installation Guide Third Edition July 2010 2010 Moxa Inc All rights reserved Reproduction without permission is prohibited Fl 4 No 135 Lane 235 Pao Chiao Rd Shing Tien City Taipei Taiwan R O C TEL 886 2 8919 1230 P N 1802005090012 ...

Страница 2: ...llation Guide y CD ROM with User s Manual and Windows utility y Moxa product warranty statement y RJ45 to DB9 console port cable y Protective caps for unused ports y Wall Mounting Kit optional must be ordered separately Mounting Dimensions unit mm Side View Front View Din Rail Kit Wall Mounting Kit Rear View 107 0 135 0 6 0 9 7 66 8 6 0 5 0 9 5 87 1 55 0 30 5 46 0 32 1 18 2 30 5 30 5 55 0 30 5 70 ...

Страница 3: ... input 1 5 PWR2 LED for power input 2 6 FAULT LED indicator 7 MSTR HEAD LED 8 CPLR TAIL LED 9 Model Name 10 10 100 1000BaseT X LED indicator Amber 10 100M Green 1000M Top Panel 1 Grounding screw 2 RS 232 console port 3 DIP switches for Ring Master Ring Coupler and Turbo Ring 4 Heat dissipation orifices 5 6 pin terminal block for DI 1 DI 2 and PWR 2 6 6 pin terminal block for PWR1 Relay 1 and Relay...

Страница 4: ...onal For some applications you will find it convenient to mount Moxa EDS G509 on the wall as shown in the following illustrations STEP 1 Remove the aluminum DIN Rail attachment plate from the rear panel of the EDS G509 and then attach the wall mount plates with M3 screws as shown in the figure at the right Ö STEP 2 Mounting the EDS G509 on the wall requires 4 screws Use the EDS G509 with wall moun...

Страница 5: ...evices are designed for operation with a Safety Extra Low Voltage Thus they may only be connected to the supply voltage connections and to the signal contact with the Safety Extra Low Voltages SELV in compliance with IEC950 EN60950 1 VDE0805 ATTENTION This unit is a built in type When the unit is installed in another piece of equipment the equipment enclosing the unit must comply with fire enclosu...

Страница 6: ... electromagnetic interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices ATTENTION This product is intended to be mounted to a well grounded mounting surface such as a metal panel Wiring the Relay Contact The EDS G509 has two sets of relay outputs relay 1 and relay 2 Each relay contact uses two contacts of the terminal block on the EDS ...

Страница 7: ... 6 pin terminal block connector on the EDS G509 s top panel which are used for the two DC inputs The top and front views of one of the terminal block connectors are shown here I1 D 2 I I2 D 1 I I1 I2 D 2 I D 1 I STEP 1 Insert the negative ground positive DI wires into the I1 terminals respectively STEP 2 To keep the DI wires from pulling loose use a small flat blade screwdriver to tighten the wire...

Страница 8: ...seT X ports located on Moxa EtherDevice Switch s front panel are used to connect to Ethernet enabled devices Most users will choose to configure these ports for Auto MDI MDI X mode in which case the port s pinouts are adjusted automatically depending on the type of Ethernet cable used straight through or cross over and the type of device NIC type or HUB Switch type connected to the port In what fo...

Страница 9: ...DC DC DD DD DD DD DC DC Tx Tx Rx Rx Switch Port NIC Port Cable Wiring Rx Rx Tx Tx DC DC DD DD DD DD DC DC 3 6 1 2 4 5 7 8 1 2 3 6 7 8 4 5 100 BaseFX or 1000BaseSFP Fiber Port The Gigabit Ethernet ports on the EDS G509 series are SFP slots which require 100BaseFX SFP or Gigabit mini GBIC fiber transceivers to work properly Moxa provides complete transceiver models for various distance requirements ...

Страница 10: ...Cable Wiring Tx Rx A B Cable Wiring A A B B A B ATTENTION This is a Class 1 Laser LED product To avoid causing serious damage to your eyes do not stare directly into the Laser Beam Turbo Ring DIP Switch Settings EDS G509 series are plug and play managed redundant Ethernet switches The proprietary Turbo Ring protocol was developed by Moxa to provide better network reliability and faster recovery ti...

Страница 11: ...Ring Coupling backup port ON Enables this EDS as the Ring Master ON Enables the default Ring Coupling port ON Activates DIP switches 1 2 3 to configure Turbo Ring V2 settings OFF Enables the default Ring Coupling primary port OFF This EDS will not be the Ring Master OFF Do not use this EDS as a ring coupler OFF DIP switches 1 2 3 will be disabled NOTE You must enable the Turbo Ring function first ...

Страница 12: ...9 is set as the Master of the Turbo Ring or as the Head of the Turbo Chain Blinking The EDS G509 has become the Ring Master of the Turbo Ring or the Head of the Turbo Chain after the Turbo Ring or the Turbo Chain is down MSTR HEAD GREEN Off When the EDS G509 is not the Master of this Turbo Ring or is set as the Member of the Turbo Chain On When the EDS G509 coupling function is enabled to form a b...

Страница 13: ...ct Two relay outputs with current carrying capacity of 1A 24 VDC Digital Input Two inputs with the same ground but electrically isolated from the electronics For state 1 13 to 30 V For state 0 30 to 3 V Max input current 8 mA Optical Fiber 100 or 1000Base SFP modules Gigabit Ethernet SFP SX SFP LSX SFP LX SFP LH SFP LHX SFP ZX SFP EZX Wave length 850 nm 1310 nm 1310 nm 1310 nm 1310 nm 1550 nm 1550...

Страница 14: ...ion Present Reverse Polarity Protection Present Mechanical Casing IP30 protection metal case Dimensions W H D 87 1 135 107 mm 3 43 5 31 4 21 in Weight 1 41 kg Installation DIN Rail Wall Mounting Kit optional kit Environment Operating Temperature 0 to 60 C 32 to 140 F standard models 40 to 75 C 40 to 167 F for T models Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non...

Страница 15: ...Information www moxa com support Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 10 6872 3958 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 ...

Отзывы: