- 12 -
paper clip or toothpick, to depress the Reset button. This will cause the
STATE LED to blink once a second. After depressing the button for 5
continuous seconds, the STATE LED will start to blink rapidly. This
indicates that factory default settings have been loaded and you can
release the reset button.
When the ABC-02-USB is connected to the EDS-G500E Ethernet switch,
the reset button allows quick configuration and backs up log files to the
ABC-02-USB. Press the Reset button on top of the EDS-G500E, the
Ethernet switch will start backing up current system configuration files
and event logs to the ABC-02-USB.
NOTE
Do NOT power off the Ethernet switch when loading default
settings.
Turbo Ring DIP Switch Settings
EDS-G500E series are plug-and-play managed redundant Ethernet
switches. The proprietary Turbo Ring protocol was developed by Moxa to
provide better network reliability and faster recovery time. Moxa Turbo
Ring’s recovery time is less than 300 ms (
Turbo Ring
) or 50 ms (
Turbo
Ring V2
) —compared to a 3- to 5-minute recovery time for commercial
switches—decreasing the possible loss caused by network failures in an
industrial setting.
There are 4 Hardware DIP Switches for Turbo Ring on the top panel of
EDS-G500E series that can help setup the Turbo Ring easily within
seconds. If you do not want to use a hardware DIP switch to setup the
Turbo Ring, you can use a web browser, telnet, or console to disable this
function.
NOTE
Please refer to the
Turbo Ring
section in
Communication
Redundancy
User's Manual for more detail information about
the setting and usage of
Turbo Ring
and
Turbo Ring V2
.
EDS-G500E Series DIP Switches
The default setting for each DIP Switch is OFF. The
following table explains the effect of setting the DIP
Switch to the ON position.
“Turbo Ring” DIP Switch Settings
DIP 1
DIP 2
DIP 3
DIP 4
Reserved for
future use.
ON: Enables this
EDS as the Ring
Master.
ON: Enables the
default “Ring
Coupling” ports.
ON: Activates
DIP switch 2 and
3 to configure
“Turbo Ring”
settings.
OFF: This EDS
will not be the
Ring Master.
OFF: Do not use
this EDS as the
ring coupler.
OFF: DIP switch
1, 2, and 3 will be
disabled.
Содержание EtherDevice EDS-G508E
Страница 5: ...5 Mounting Dimensions Unit mm inch...