4
DIN-Rail Mounting
The DIN-Rail attachment plates are permanently fixed to the back panel of the
EDS-728/828. Do not attempt to remove the attachment plates, since doing so
could damage the product
.
To Install:
Lock the brace by pressing the clips and then insert the top of the DIN-Rail
into the notches at the bottom of the top array of heat radiating ribs. Press the
EDS until the brace snaps into place.
To Release:
Use a flat-blade screw driver as a lever to force the braces downwards, and
then pull the EDS-728/828 out away from the DIN-Rail.
Wall Mounting (optional)
For some applications, you will find it convenient to mount the EDS-728/828
on the wall, as illustrated below.
STEP 1
: Remove the aluminum DIN-Rail attachment plate from the
EDS-728/828’s rear panel, and then attach the wall mounting plates, as shown
in the diagram.