Wiring the Redundant Power Inputs
The top two contacts and the bottom two contacts of the 6-contact
terminal block connector on the EDS’s top panel are used for the EDS’s
two AC/ DC inputs. Top and front views of one of the terminal block
connectors are shown here.
STEP 1:
Insert the negative/positive AC/ DC wires into
the V-/V+ terminals.
STEP 2:
To keep the AC/ DC wires from pulling loose,
use a small flat-blade screwdriver to tighten
the wire-clamp screws on the front of the
terminal block connector.
STEP 3:
Insert the plastic terminal block connector
prongs into the terminal block receptor, which
is located on EDS’s top panel.
ATTENTION
Before connecting the EDS to the AC/DC power inputs, make sure
the AC/DC power source voltage is stable.
Communication Connections
EDS-G308 models have 8 10/100/1000BaseT(X) Ethernet ports, or 6
10/100/1000BaseT(X) and 2 combination ports—10/100/1000T(X) and
100/1000BaseSFP.
10/100/1000BaseT(X) Ethernet Port Connection
The 10/100/1000BaseT(X) ports located on Moxa EtherDevice Switch’s
front panel are used to connect to Ethernet-enabled devices. Most users
will choose to configure these ports for Auto MDI/MDI-X mode, in which
case the port’s pinouts are adjusted automatically depending on the type
of Ethernet cable used (straight-through or cross-over), and the type of
device (NIC-type or HUB/Switch-type) connected to the port.
In what follows, we give pinouts for both MDI (NIC-type) ports and MDI-X
(HUB/Switch-type) ports. We also give cable wiring diagrams for
straight-through and cross-over Ethernet cables.
10 /100Base T(x) RJ45 Pinouts
MDI Port Pinouts
MDI-X Port Pinouts
8-pin RJ45
Pin
Signal
1
Tx+
2
Tx-
3
Rx+
6
Rx-
Pin
Signal
1
Rx+
2
Rx-
3
Tx+
6
Tx-