background image

 

- 6 - 

STEP 3: 
Once the screws are fixed in the 
wall, insert the four screw heads 
through the large parts of the 
keyhole-shaped apertures, and then 
slide the EDS downwards, as 
indicated. Tighten the four screws 
for added stability. 

 

  ATEX Information 

1.

 

Certificate number DEMKO 10 ATEX 0917324X 

2.

 

Ambient range (-40°C ≤ Tamb ≤ 75°C) 

3.

 

Certification string (Ex nA nC IIC T4 Gc) 

 

4.

 

Standards covered (EN 60079-0:2012, EN 60079-15:2010) 

5.

 

The conditions of safe usage: 

 

Subject devices are for use in ambient temperature -40°C 
≤Tamb ≤ +75°C. 

 

Subject devices are to be installed in an IP54 enclosure. 

 

Subject devices are for use in an area of not more than pollution 
degree 2 in accordance with IEC 60664-1. 

 

Subject devices are to use Conductors suitable for use in an 
ambient temperature of 100°C must be used for the Power 
Supply Terminal. 

Wiring Requirements 

 

WARNING 

Safety First!

 

Turn the power off before disconnecting modules or wires. The 
proper power supply voltage is listed on the product label. Check 
the voltage of your power source to make sure you are using the 
correct voltage. Do NOT use a voltage greater than what is 
specified on the product label. 
These devices must be supplied by an AELV source as defined in 
the Low Voltage Directive 2006/95/EC and 2004/108/EC. 

 

 

 

WARNING 

Safety First!

 

Calculate the maximum possible current in each power wire and 
common wire. Observe all electrical codes dictating the 
maximum current allowable for each wire size. 
If the current goes above the maximum ratings, the wiring could 
overheat, causing serious damage to your equipment. 

 

 
 

Содержание EDS-G308

Страница 1: ... 2014 Moxa Inc All rights reserved P N 1802003082013 EDS G308 Hardware Installation Guide Moxa EtherDevice Switch Fourth Edition April 2014 ...

Страница 2: ...use EDS as an abbreviation for Moxa EtherDevice Switch EDS Moxa EtherDevice Switch Package Checklist Your EDS is shipped with the following items If any of these items is missing or damaged please contact your customer service representative for assistance Moxa EtherDevice Switch Hardware Installation Guide Moxa Product Warranty booklet Protective caps for unused ports Features High Performance Ne...

Страница 3: ...t PWR1 PWR2 and relay output 3 Power input PWR1 LED 4 Power input PWR2 LED 5 Fault LED 6 TP port s 10 10 1000 Mbps LED 7 Port number 8 10 100 1000BaseT X Port 9 100 1000Base SFP slot 10 Model Name 11 DIP switches 12 Heat dissipation orifices 13 Screw hole for wall mounting kit 14 DIN rail Kit ...

Страница 4: ... 4 Mounting Dimensions Unit mm inch ...

Страница 5: ...n the wall as illustrated below STEP 1 Remove the aluminum DIN rail attachment plate from the EDS s rear panel and then attach the wall mount plates as shown in the figure STEP 2 Mounting the EDS on the wall requires 4 screws Use the switch with wall mount plates attached as a guide to mark the correct locations of the 4 screws The heads of the screws should be less than 6 0 mm in diameter and the...

Страница 6: ... 1 Subject devices are to use Conductors suitable for use in an ambient temperature of 100 C must be used for the Power Supply Terminal Wiring Requirements WARNING Safety First Turn the power off before disconnecting modules or wires The proper power supply voltage is listed on the product label Check the voltage of your power source to make sure you are using the correct voltage Do NOT use a volt...

Страница 7: ...erference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices ATTENTION This product is intended to be mounted to a well grounded mounting surface such as a metal panel Wiring the Alarm Contact The Alarm Contact consists of the two middle contacts of the terminal block on the EDS s top panel You may refer to the next section for detailed instruc...

Страница 8: ...able Communication Connections EDS G308 models have 8 10 100 1000BaseT X Ethernet ports or 6 10 100 1000BaseT X and 2 combination ports 10 100 1000T X and 100 1000BaseSFP 10 100 1000BaseT X Ethernet Port Connection The 10 100 1000BaseT X ports located on Moxa EtherDevice Switch s front panel are used to connect to Ethernet enabled devices Most users will choose to configure these ports for Auto MD...

Страница 9: ...are SFP type slots which support both 100Base FX and 1000Base X speed fiber transceiver to work properly Moxa provides complete transceiver models for various distance requirements Multi mode 1000BaseSX 0 to 550 m 850 nm 50 125μm 400MHz km 0 to 275 m 850 nm 62 5 125μm 200MHz km 1000BaseLX 0 to 1100 m 1310 nm 50 125μm 800MHz km 0 to 550 m 1310 nm 62 5 125μm 500MHz km Single mode 1000BaseLX 0 to 10 ...

Страница 10: ...oduct To avoid causing serious damage to your eyes do not stare directly into the Laser Beam Redundant Power Inputs Both power inputs can be connected simultaneously to live AC DC power sources If one power source fails the other live source acts as a backup and automatically supplies all of the EDS s power needs Alarm Contact The Moxa EtherDevice Switch has one Alarm Contact located on the top pa...

Страница 11: ... form a closed circuit and the Fault LED will never light up ATTENTION To actively update DIP switch settings power off and then power on the EDS LED Indicators The front panel of the Moxa EtherDevice Switch contains several LED indicators The function of each LED is described in the table below LED Color State Description PWR1 AMBER On Power is being supplied to power input PWR1 Off Power is not ...

Страница 12: ...alf duplex depending on which transmission speed is supported by the attached device Auto Negotiation and Speed Sensing The EDS s RJ45 Ethernet ports independently support auto negotiation for transmission speeds of 10 Mbps 100 Mbps and 1000 Mbps with operation according to the IEEE802 3 standard This means that some nodes could be operating at 10 Mbps while at the same time other nodes are operat...

Страница 13: ...e b 62 5 125 μm 200 MHz km fiber optic cable c 50 125 μm 800 MHz km fiber optic cable d 62 5 125 μm 500 MHz km fiber optic cable e 9 125 μm 3 5 PS nm km fiber optic cable f 9 125 μm 19 PS nm km fiber optic cable 100Base Ethernet Multi Mode Single Mode Wavelength 1300 nm 1310 nm Max TX 10 dBm 0 dBm Min TX 20 dBm 5 dBm RX Sensitivity 32 dBm 34 dBm Link Budget 12 dB 29 dB Typical Distance 5 kma 4 kmb...

Страница 14: ...ss A EMS EN 61000 4 2 ESD Level 3 EN 61000 4 3 RS Level 3 EN 61000 4 4 EFT Level 3 EN 61000 4 5 Surge Level 3 EN 61000 4 6 CS Level 3 EN 61000 4 8 EN 61000 4 11 EN 61000 4 12 Shock IEC 60068 2 27 Free Fall IEC 60068 2 32 Vibration IEC 60068 2 6 WARRANTY 5 years Technical Support Contact Information www moxa com support Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Mo...

Отзывы: