NOTE

 

Before tightening the screws into the wall, make sure the screw 
head and shank size are suitable by inserting the screw into one of 
the keyhole-shaped apertures of the Wall Mounting Plates. 

Do not screw the screws in all the way—leave about 2 mm to allow room for 
sliding the wall mount panel between the wall and the screws.

 

STEP 3

: Once the screws are fixed in the wall, insert the four screw heads 

through the large parts of the keyhole-shaped apertures, and then slide Moxa 
EDS downwards, as indicated. Tighten the four screws for added stability. 

EtherDevice Switch

EDS-726

EtherDevice Switch

EDS-726

 

Wiring Requirements 

 

WARNING 

Safety First!

 

Be sure to disconnect the power cord before installing and/or 
wiring your Moxa EDS-726. 
Calculate the maximum possible current in each power wire and 
common wire. Observe all electrical codes dictating the 
maximum current allowable for each wire size. 
If the current goes above the maximum ratings, the wiring could 
overheat, causing serious damage to your equipment.

 

 

You should also pay attention to the following guidelines: 

y

 

Use separate paths to route wiring for power and devices. If power wiring 
and device wiring paths must cross, make sure the wires are perpendicular 
at the intersection point. 

y

 

NOTE: Do not run signal or communications wiring and power wiring in 
the same wire conduit. To avoid interference, wires with different signal 
characteristics should be routed separately. 

y

 

You can use the type of signal transmitted through a wire to determine 
which wires should be kept separate. The rule of thumb is that wiring that 
shares similar electrical characteristics can be bundled together. 

Содержание EDS-726 Series

Страница 1: ...Moxa EtherDevice Switch EDS 726 Hardware Installation Guide Second Edition June 2008 2008 Moxa Inc all rights reserved Reproduction without permission is prohibited P N 1802007260011...

Страница 2: ...ULT MASTER PWR2 LNK ACT SPEED IM 1GSXSC IM 1GTX IM 4MSC TX RX 3 4 TX RX 1 2 PWR P3 P1 P4 P2 IM 4MST TX RX 3 4 TX RX 1 2 PWR P3 P1 P4 P2 3 4 IM 4TX 1 2 PWR P3 P1 P4 P2 RS 232 Console Load Save CF 1 2 5...

Страница 3: ...or 2 power inputs 2 DIs and 2 DOs 6 Save and load buttons for CF card 7 Serial Console port 8 CF card socket 9 Gigabit Ethernet Module LEDs 10 Two cartridge receptors for Gigabit Ethernet Interface Mo...

Страница 4: ...View EtherDevice Switch EDS 726 106 63 149 15 362 40 401 00 Rear View 128 00 146 47 140 00 Side View Gigabit Ethernet Interface Modules Front View Side View 101 20 95 60 59 00 66 20 66 20 24 Fast Eth...

Страница 5: ...om the DIN Rail The DIN Rail attachment plates have an internal spring that keeps the attachment plate pushed upwards DIN Rail DIN Rail brace Wall Mounting optional For some applications you will find...

Страница 6: ...oxa EDS 726 Calculate the maximum possible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above...

Страница 7: ...the terminal block connector to the terminal block receptor RELAY1 RELAY2 PWR1 PWR2 V2 V2 V1 V1 DI1 I1 I2 DI2 Top View Front View FAULT The two sets of relay contacts of the 6 pin terminal block conn...

Страница 8: ...rts on EDS 726 connect to other devices Pinouts are diagrams that indicate the type of signal passing through each of the port s pins NOTE 1 The pin numbers for male DB9 and DB25 connectors and hole n...

Страница 9: ...he SC ST port and cable is quite straightforward Suppose you are connecting devices I and II Contrary to electrical signals optical signals do not require a circuit in order to transmit data Consequen...

Страница 10: ...input PWR1 PWR1 AMBER Off Power is not being supplied to the main module s power input PWR1 On Power is being supplied to the main module s power input PWR2 PWR2 AMBER Off Power is not being supplied...

Страница 11: ...rt s data is not being transmitted On The corresponding module s port is the ring port of this EDS 726 RING PORT GREEN Off The corresponding module s port is not the ring port of this EDS 726 On The c...

Страница 12: ...6 slots for any combination of 4 port Interface Modules with 10 100BaseT X or 100BaseFX Gigabit Ethernet 2 sockets for any combination of 1 port Interface Modules with 10 100 1000BaseT X 1000BaseSX 10...

Страница 13: ...port SC connector IM 1GLXSC Interface Module with 1 1000BaseLX port SC connector IM 1GLHXSC Interface Module with 1 1000BaseLHX port SC connector 40 km IM 1GZXSC Interface Module with 1 1000BaseZX po...

Страница 14: ...45 connectors IM 4MSC Interface Module with 4 multi mode 100BaseFX ports SC connectors IM 4MST Interface Module with 4 multi mode 100BaseFX ports ST connectors IM 4SSC Interface Module with 4 single m...

Страница 15: ...er Ports 100BaseFX ports SC ST connector Optical Fiber Distance Multi mode IM 4MSC IM 4MST IM 2MSC 2TX IM 2MST 2TX 0 to 5 km 1310 nm 50 125 m 800 MHz km 0 to 4 km 1310 nm 62 5 125 m 500 MHz km Single...

Страница 16: ...00 4 4 EFT Level 3 EN61000 4 5 Surge Level 3 EN61000 4 6 CS Level 3 EN61000 4 8 EN61000 4 11 EN61000 4 12 Shock IEC60068 2 27 Free Fall IEC60068 2 32 Vibration IEC60068 2 6 WARRANTY 5 years Technical...

Отзывы: