DIN-Rail Mounting
The DIN-Rail attachment plates are permanently fixed to the back panel of
EDS-726. Do not attempt to remove the attachment plates, since doing so could
damage the product
.
STEP 1
:
Insert the top of the DIN-Rail into the
notches at the bottom of the top array
of heat radiating ribs.
STEP 2
:
The bottom of the DIN-Rail will snap
into place behind the DIN-Rail
attachment plate.
DIN-Rail
DIN-Rail
brace
DIN-Rail
DIN-Rail
brace
As shown in the figure at the right,
use a flat-blade screw driver as a lever
to force the DIN-Rail attachment
plates downwards, and then pull
EDS-726 out away from the
DIN-Rail. The DIN-Rail attachment
plates have an internal spring that
keeps the attachment plate pushed
upwards.
DIN-Rail
DIN-Rail
brace
Wall Mounting (optional)
For some applications, you will find it convenient to mount EDS-726 on the
wall, as illustrated below.
STEP 1
: Remove the aluminum DIN-Rail attachment plate from EDS-726’s
rear panel, and then attach the wall mounting plates, as shown in the diagram.
STEP 2
:
Mounting EDS-726 on the wall requires 4 screws to ensure
that the switch does not come loose from the wall. Use the
switch, with wall mounting plates attached, as a guide to
mark the correct locations of the 4 screws. The heads of the
screws should be less than 6.0 mm in diameter, and the
shafts should be less than 3.5 mm in diameter, as shown in
the figure at the right.
6.0 mm
3.5 mm