background image

 

 12 

LED Indicators 

The front panel of MOXA EDS-516A contains several LED indicators. The 
function of each LED is described in the 

following table:

 

LED 

Color 

State 

Description 

On 

Power is being supplied to power 

input P1. 

PWR1 

AMBER

Off 

Power is 

not

 being supplied to power 

input P1. 

On 

Power is being supplied to power 

input P2. 

PWR2 

AMBER

Off 

Power is 

not

 being supplied to power 

input P2. 

On 

When the corresponding PORT alarm 

is enabled, and a user-configured 

event is triggered. 

FAULT 

RED 

Off 

When the corresponding PORT alarm 

is enabled and a user-configured 

event is not triggered, or when the 

corresponding PORT alarm is 

disabled. 

On 

When the EDS-516A is the Master of 

this Turbo Ring 

MASTER 

GREEN

Blinking

When the EDS-516A is Ring Master 

of this Turbo Ring and the Turbo Ring 

is broken. 

On 

When the EDS-516A enables the 

coupling function to form a back-up 

path. 

COUPLER 

GREEN

Off 

When the EDS-516A disables the 

coupling function. 

On 

TP port’s 10 Mbps link is active. 

Blinking Data is being transmitted at 10 Mbps. 

10M 
(TP) 

GREEN

Off 

TP port’s 10 Mbps link is inactive. 

On 

TP port’s 100 Mbps link is active. 

Blinking Data is being transmitted at 100 

Mbps. 

100M 

(TP) 

GREEN

Off 

TP port’s 100 Mbps link is inactive. 

On 

FX port’s 100 Mbps link is active. 

Blinking Data is being transmitted at 100 

Mbps. 

100M 

(FX) 

GREEN

Off 

FX port’s 100 Mbps link is inactive. 

 

 

 

 

Содержание EDS-516A Series

Страница 1: ...S 516A Series Hardware Installation Guide First Edition November 2006 Moxa Networking Co Ltd Tel 886 2 2910 1230 Fax 886 2 2910 1231 www moxa com support moxanet com Worldwide support usa moxa com The Americas P N 1802005160000 ...

Страница 2: ...oxa Product Warranty Booklet y RJ45 to DB9 Console port cable y Protective caps for unused ports y Panel mounting kit optional must order separately Optional Accessories y DR 4524 45W 2A DIN Rail 24 VDC Power Supply with 85 to 264 VAC input y DR 75 24 75W 3 2A DIN Rail 24 VDC Power Supply with 85 to 264 VAC input y DR 120 24 120W 5A DIN Rail 24 VDC Power Supply with 88 to 132 VAC 176 to 264 VAC in...

Страница 3: ...inal block for DI 1 DI 2 and PWR 2 5 6 pin terminal block for PWR1 Relay 1 and Relay 2 6 10 100BaseT X ports 1 to 16 7 PWR 1 LED for power input 1 8 PWR 2 LED for power input 2 9 Fault LED 10 MASTER LED 11 COUPLER LED 12 Turbo Ring logo 13 TP port s 100 Mbps LED 14 TP port s 10 Mbps LED 15 Model Name 16 Screw hole for Wall Mounting Kit 17 DIN Rail Kit ...

Страница 4: ...s 4 6 pin terminal block for DI 1 DI 2 and PWR 2 5 6 pin terminal block for PWR1 Relay 1 and Relay 2 6 10 100BaseT X ports 1 to 14 7 PWR 1 LED for power input 1 8 PWR 2 LED for power input 2 9 Fault LED 10 MASTER LED 11 COUPLER LED 12 Turbo Ring logo 13 TP port s 100 Mbps LED 14 TP port s 10 Mbps LED 15 Model Name 16 100BaseFX Port 15 17 100BaseFX Port 16 18 100BaseFX LEDs 19 Screw hole for Wall M...

Страница 5: ...ounting The aluminum DIN Rail attachment plate should already be fixed to the back panel of EDS 516A when you take it out of the box If you need to reattach the DIN Rail attachment plate to EDS 516A make sure the stiff metal spring is situated towards the top as shown by the following figures STEP 1 Insert the top of the DIN Rail into the slot just below the stiff metal spring STEP 2 The DIN Rail ...

Страница 6: ...ze are suitable by inserting the screw through one of the keyhole shaped apertures of the Wall Mounting Plates Do not screw the screws in all the way leave about 2 mm to allow room for sliding the wall mount panel between the wall and the screws STEP 3 Once the screws are fixed on the wall insert the four screw heads through the wide parts of the keyhole shaped apertures and then slide EDS 516A do...

Страница 7: ...al characteristics should be routed separately y You can use the type of signal transmitted through a wire to determine which wires should be kept separate The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together y Separate input wiring and output wiring y We advise that you label wiring to all devices in the system when necessary Grounding MOXA EDS 5...

Страница 8: ...To keep the DC wires from pulling loose use a small flat blade screwdriver to tighten the wire clamp screws on the front of the terminal block connector STEP 3 Insert the plastic terminal block connector prongs into the terminal block receptor which is located on EDS 516A s top panel Wiring the Digital Inputs EDS 516A has two sets of digital inputs DI 1 and DI 2 Each DI consists of two contacts of...

Страница 9: ...formation 1 When building your own cable refer to the pin to pin Cable Wiring information displayed between the two vertical dashed lines to see which pin of the connector on the left should be connected to which pin of the connector on the right 2 The information to the left of the left vertical dashed lines gives the pinouts of the relevant MOXA EtherDevice Switch port 3 The information to the r...

Страница 10: ...ation utility RJ45 10 pin Console Port Pinouts Pin Description 1 2 DSR 3 4 GND 5 TxD 6 RxD 7 GND 8 9 DTR 10 1 10 RJ45 10 pin to DB9 F Cable Wiring RJ45 Plug Pin 1 Moxa EtherDevice Server RJ45 Connector DCD DSR RTS GND TxD RxD CTS DTR COM Port Female DB9 Connector DCD DTR CTS GND RxD TxD RTS DSR Cable Wiring 1 2 3 4 7 5 6 8 9 1 6 7 5 3 2 8 4 RJ45 10 pin to DB25 F Cable Wiring RJ45 Plug Pin 1 Moxa E...

Страница 11: ... NIC type ports and MDI X HUB Switch type ports We also give cable wiring diagrams for straight through and cross over Ethernet cables RJ45 8 pin MDI Port Pinouts Pin Signal 1 Tx 2 Tx 3 Rx 6 Rx 1 8 RJ45 8 pin MDI X Port Pinouts Pin Signal 1 Rx 2 Rx 3 Tx 6 Tx 1 8 RJ45 8 pin to RJ45 8 pin Straight Through Cable Wiring Straight Through Cable RJ45 Plug Pin 1 Switch Port RJ45 Connector RJ45 Connector T...

Страница 12: ...l you need to remember is to connect the Tx transmit port of device I to the Rx receive port of device II and the Rx receive port of device I to the Tx transmit port of device II If you are making your own cable we suggest labeling the two sides of the same line with the same letter A to A and B to B as shown by the following illustration or A1 to A2 and B1 to B2 SC Port Pinouts SC Port to SC Port...

Страница 13: ...t triggered or when the corresponding PORT alarm is disabled On When the EDS 516A is the Master of this Turbo Ring MASTER GREEN Blinking When the EDS 516A is Ring Master of this Turbo Ring and the Turbo Ring is broken On When the EDS 516A enables the coupling function to form a back up path COUPLER GREEN Off When the EDS 516A disables the coupling function On TP port s 10 Mbps link is active Blink...

Страница 14: ... and auto MDI MDI X connection Fiber Ports 100BaseFX SC ST connector Console RS 232 RJ45 LED Indicators PWR1 PWR2 FAULT 10 100M TP port 100M Fiber port Ring Master and Ring Coupler Alarm Contact Two relay outputs with current carrying capacity of 1A 24 VDC Digital Input Two inputs with the same ground but electrically isolated from the electronics For state 1 13 to 30V For state 0 30 to 3V Max inp...

Страница 15: ...e 0 to 60 C 32 to 140 F 40 to 75 C 40 to 167 F for T models Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non condensing Regulatory Approvals Safety UL 508 Pending UL60950 1 CSA C22 2 No 60950 1 EN60950 1 Hazardous Location UL cUL Class I Division 2 Groups A B C and D ATEX Class I Zone 2 EEx nC IIC Pending EMI FCC Part 15 CISPR EN55022 class A EMS EN61000 4 2 ESD Lev...

Страница 16: ...the full benefit of our products Moxa has set up on line support services to provide technical support driver updates product information and user s manual updates E mail for technical support support moxa com Worldwide support usa moxa com The Americas Website for up to date product information www moxa com ...

Отзывы: