- 14 -
NOTE If you do not enable any of the EDS-405A/408A switches to be
the Ring Master, the Turbo Ring protocol will automatically
choose the EDS-405A/408A with the smallest MAC address range
to be the Ring Master. If you accidentally enable more than one
EDS-405A/408A to be the Ring Master, these EDS-405A/408A
switches will auto-negotiate to determine which switch will be the
Ring Master.
NOTE To switch on the Master or Coupler functions of the DIP switch,
you need to enable the Turbo Ring Pole first.
LED Indicators
There are several LEDs on the EDS’s front panel. The function of each LED
is described in the following table.
LED
Color
State
Description
PWR1
AMBER
On
Power is being supplied to power input
PWR1.
Off
Power is not being supplied to power
input PWR1.
PWR2
AMBER
On
Power is being supplied to power input
PWR2.
Off
Power is not being supplied to power
input PWR2.
FAULT
RED
On
When (1) a relay warning event is
triggered, (2) the EDS-405A/408A is
the Master of this Turbo Ring, and the
Turbo Ring is broken, or (3) start-up
failure.
Off
When a relay warning event is not
triggered.
MSTR/HEAD GREEN
On
When the EDS-405A/408A is set as the
Master of the Turbo Ring, or as the
Head of the Turbo Chain.
Blinking
The EDS-405A/408A has become the
Ring Master of the Turbo Ring, or the
Head of the Turbo Chain, after the
Turbo Ring or the Turbo Chain is down.
Off
When the EDS-405A/408A is not the
Master of this Turbo Ring or is set as
the Member of the Turbo Chain.
CPLR/TAIL GREEN
On
When the EDS-405A/408A coupling
function is enabled to form a back-up
path, or when it's set as the Tail of the
Turbo Chain.
Blinking When the Turbo Chain is down.
Off
When the EDS-405A/408A disables the
coupling function, or is set as the
Member of the Turbo Chain.
10M
(TP)
GREEN
On
TP port’s 10 Mbps link is active.
Blinking Data is being transmitted at 10 Mbps.
Off
TP Port’s 10 Mbps link is inactive.