background image

 

 
 
 
 
 

Moxa EtherDevice Switch 

EDS-305 

Hardware Installation Guide 

 
 
 
 
 
 
 
 
 
 

Eighth Edition, September 2010 

 
 
 
 
 
 
 
 
 
 

 

©

 2010 Moxa Inc. All rights reserved. 

Reproduction without permission is prohibited. 

Fl.4, No.135, Lane 235, Pao-Chiao Rd. Shing Tien City, Taipei, Taiwan, 

R.O.C. 

TEL: +886-2-8919-1230 

 

P/N: 1802003050030 

Содержание EDS-309

Страница 1: ...re Installation Guide Eighth Edition September 2010 2010 Moxa Inc All rights reserved Reproduction without permission is prohibited Fl 4 No 135 Lane 235 Pao Chiao Rd Shing Tien City Taipei Taiwan R O C TEL 886 2 8919 1230 P N 1802003050030 ...

Страница 2: ...epresentative for assistance y Moxa EtherDevice Switch y Hardware Installation Guide y Moxa Product Warranty booklet y Protective caps for unused ports Features High Performance Network Switching Technology y 10 100BaseT X RJ45 100BaseFX SC ST type Multi Single mode y IEEE802 3 802 3u 802 3x y Store and Forward switching process type with 1024 address entries y 10 100M Full Half Duplex MDI MDIX au...

Страница 3: ... 2 3 4 1 Rear Panel View 2 13 12 12 1 Grounding screw 2 Terminal block for power inputs PWR1 PWR2 and relay output 3 Heat dissipation orifices 4 DIP switches 5 Power input PWR1 LED 6 Power input PWR2 LED 7 Fault LED 8 10 100BaseT X Port 9 TP port s 100 Mbps LED 10 TP port s 10 Mbps LED 11 Model Name 12 Screw holes for wall mounting kit 13 DIN rail Kit ...

Страница 4: ...appearance of EDS 305 S SC is identical to EDS 305 M SC 1 Grounding screw 2 Terminal block for power inputs PWR1 PWR2 and relay output 3 Heat dissipation orifices 4 DIP switches 5 Power input PWR1 LED 6 Power input PWR2 LED 7 Fault LED 8 10 100BaseT X Port 9 TP port s 100 Mbps LED 10 TP port s 10 Mbps LED 11 Model Name 12 100BaseFX Port 13 FX port s 100 Mbps LED 14 Screw holes for wall mounting ki...

Страница 5: ...rminal block for power input PWR1 PWR2 and relay output 3 Heat dissipation orifices 4 DIP switches 5 Power input PWR1 LED 6 Power input PWR2 LED 7 Fault LED 8 10 100BaseT X Port 9 TP port s 100 Mbps LED 10 TP port s 10 Mbps LED 11 Model Name 12 100BaseFX Port 13 100 Mbps LED for FX port 14 Screw hole for wall mounting kit 15 DIN rail Kit 16 100 Mbps LED for FX port 7 17 100 Mbps LED for FX port 8 ...

Страница 6: ...rail attachment plate should already be fixed to the back panel of the EDS when you take it out of the box If you need to reattach the DIN rail attachment plate make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 Insert the top of the DIN rail into the slot just below the stiff metal spring STEP 2 The DIN rail attachment unit will snap into place as sh...

Страница 7: ...screws in all the way leave about 2 mm to allow room for sliding the wall mount panel between the wall and the screws STEP 3 Once the screws are fixed in the wall insert the four screw heads through the large parts of the keyhole shaped apertures and then slide the EDS downwards as indicated Tighten the four screws for added stability II 3G ATEX Information 1 Certification number DEMKO 09 ATEX 081...

Страница 8: ...sconnect the power cord before installing and or wiring your Moxa EtherDevice Switch Calculate the maximum possible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment You should also pay attention to the fol...

Страница 9: ...erminal block connector are used to detect both power faults and port faults The two wires attached to the Fault contacts form an open circuit when 1 The EDS has lost power from one of the DC power inputs OR 2 One of the ports for which the corresponding PORT ALARM DIP Switch is set to ON is not properly connected If neither of these two conditions is satisfied the Fault circuit will be closed Wir...

Страница 10: ...3 Tx 6 Rx 6 Tx RJ45 8 pin to RJ45 8 pin Straight Through Cable Wiring Straight Through Cable RJ45 Plug Pin 1 Switch Port RJ45 Connector RJ45 Connector Tx Tx Rx Rx NIC Port Cable Wiring 3 3 6 6 1 1 2 2 Rx Rx Tx Tx RJ45 8 pin to RJ45 8 pin Cross Over Cable Wiring Cross Over Cable RJ45 Plug Pin 1 Switch Port NIC Port RJ45 Connector RJ45 Connector Tx Tx Rx Rx Rx Rx Tx Tx Tx Tx Rx Rx Switch Port NIC Po...

Страница 11: ...e power source fails the other live source acts as a backup and automatically supplies all of the EDS s power needs Alarm Contact The Moxa EtherDevice Switch has one Alarm Contact located on the top panel For detailed instructions on how to connect the Alarm Contact power wires to the two middle contacts of the 6 contact terminal block connector see the Wiring the Alarm Contact section on page 8 A...

Страница 12: ...wer is not being supplied to power input PWR1 PWR2 AMBER On Power is being supplied to power input PWR2 Off Power is not being supplied to power input PWR2 FAULT RED On When the corresponding PORT alarm is enabled and the port s link is inactive Off When the corresponding PORT alarm is enabled and the port s link is active or when the corresponding PORT alarm is disabled 10M GREEN On TP port s 10 ...

Страница 13: ...to the right side so that it fits snuggly into the port slider slider guide slider ridges slider slider guide slider ridges The 100 Mbps fiber ports are switched ports and perform as a domain providing a high bandwidth backbone connection that supports long fiber cable distances up to 5 km for multi mode and 15 40 and 80 km for single mode for installation versatility Dual Speed Functionality and ...

Страница 14: ...o that as nodes are added or removed or moved from one segment to another the EDS automatically keeps up with new node locations An address aging algorithm causes the least used addresses to be deleted in favor of newer more frequently used addresses To reset the address buffer power down the unit and then power it back up Auto Negotiation and Speed Sensing All of the EDS s RJ45 Ethernet ports ind...

Страница 15: ...lay output with current carrying capacity of 1A 24 VDC Optical Fiber Multi mode Single mode 15 Single mode 40 Single mode 80 Distance km 5 15 40 80 Wavelength nm 1300 1310 1310 1550 Min TX Output dBm 20 15 5 5 Max TX Output dBm 14 6 0 0 Sensitivity dBm 34 to 30 36 to 32 36 to 32 36 to 32 Recommended Diameter Core Cladding μm 50 125 9 125 9 125 9 125 1 dB km 800 MHz km Power Input Voltage 12 to 48 ...

Страница 16: ...5022 class A EMS EN61000 4 2 ESD Level 3 EN61000 4 3 RS Level 3 EN61000 4 4 EFT Level 3 EN61000 4 5 Surge Level 3 EN61000 4 6 CS Level 3 Martime DNV GL Shock IEC60068 2 27 Free Fall IEC60068 2 32 Vibration IEC60068 2 6 WARRANTY 5 years Technical Support Contact Information www moxa com support Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office T...