For example, if a remote user (IP: 10.10.10.10) connects to the Industrial Secure Router and changes the
Trusted IP address to 10.10.10.12, or accidentally disables the Trusted IP entry and applies the changes,
the connection to the Industrial Secure Router will be lost because the IP address is no longer in the
Industrial Secure Router’s Trusted IP list.
If the user enables the Setting Check function for Trusted IP list changes and the confirm Timer is set to 15
seconds, when the user clicks the
APPLY
button on the Trusted IP list page, the Industrial Secure Router
will execute the configuration change and the web browser will attempt to go to the Setting Check
Confirmed page automatically. Because the remote user’s IP address is not in the new Trusted IP list, the
remote user cannot connect to the Setting Check Confirmed page. After 15 seconds, the timer will expire
and the Industrial Secure Router will roll back to the original Trusted IP List settings, allowing the remote
user to reconnect to the Industrial Secure Router.
If the new configuration does not block the remote user’s connection to the Industrial Secure Router, the
user will see the Setting Check Confirmed page. Click
CONFIRM
to save and apply the changes.
Содержание EDR-G9010 Series
Страница 23: ...EDR G9010 Series User Manual 23 Dynamic IP Static IP PPPoE...
Страница 71: ...EDR G9010 Series User Manual 71 Settings...
Страница 147: ...EDR G9010 Series User Manual 147...
Страница 261: ...EDR G9010 Series User Manual 261 Port Event Settings Port Events are related to the activity of a specific port...
Страница 274: ...EDR G9010 Series User Manual 274 Function Account Privilege Ping R W R W R...