Create a Modbus/TCP Profile
Modbus/TCP is a Modbus protocol used for communications over TCP/IP networks, connecting over port 502
by default. Modbus has also been experimentally used over UDP on IP networks, which removes the
overheads required for TCP. The following table shows the Modbus TCP frame format:
Modbus/TCP Frame Format
Description
Length
Function
Transaction Identifier
2 bytes
Synchronization between messages of the server and client
Protocol Identifier
2 bytes
The value is 0 for Modbus TCP protocol
Length Field
2 bytes
Number of remaining following bytes in this frame
Unit Identifier
1 byte
Slave Address (255 is used for device broadcast information)
Function code
1 byte
Defines the message type
Data bytes
n bytes
Data block with additional information
Name
Setting
Description
Factory Default
0 to 64 characters
Enter a name for the protocol filter profile.
None
Category
Setting
Description
Factory Default
Modbus/TCP
Select the Modbus/TCP protocol.
None
Function Code
Setting
Description
Factory Default
All, blank, common
function code
Select the function code or manually specify the function code.
The function code format is 0 to 255 and allows commas.
Refer to the
function codes.
None
Содержание EDR-G9010 Series
Страница 23: ...EDR G9010 Series User Manual 23 Dynamic IP Static IP PPPoE...
Страница 71: ...EDR G9010 Series User Manual 71 Settings...
Страница 147: ...EDR G9010 Series User Manual 147...
Страница 261: ...EDR G9010 Series User Manual 261 Port Event Settings Port Events are related to the activity of a specific port...
Страница 274: ...EDR G9010 Series User Manual 274 Function Account Privilege Ping R W R W R...