LED Indicators 

The front panel of the Moxa AWK-1127 contains several LED indicators. 
The function of each LED is described in the table below. 

LED 

Color 

State  Description 

PWR 

Green 

On 

Power is supplied 

Off 

Power is not supplied 

FAULT 

Red 

On 

Booting 

Blinking 

(slow) 

IP address cannot be retrieved from the 
DHCP server (interval: 1 sec) 

Blinking 

(fast) 

IP address conflict (interval: 0.5 sec) 

Off 

Normal status 

STATE 

Green/ 

Red 

Green  Software Ready 

Blinking   

Green 

The AWK Search Utility has located the 
AWK (interval: 1sec) 

Red 

Boot or device error   

SIGNAL 

(5 LEDs) 

Green 

On 

Signal level 

Off 

Reserved 

WLAN 

Green 

On 

WLAN is established 

Blinking  WLAN is transmitting data   

Off 

WLAN is not established or is not 
working properly 

LAN 

Green 

On 

100/10 Mbps LAN port is active 

Blinking  Data is being transmitted 

Off 

100/10 Mbps LAN port is inactive 

TX/RX 

Green 

On 

Serial port is transmitting data. 

Off 

No data is being received through the 
serial port. 

Amber 

On 

Serial port is receiving data. 

Off 

No data is being transmitted through 
the serial port. 

Specifications 

WLAN Interface 

Standards 

IEEE 802.11a/b/g for Wireless LAN 
IEEE 802.3u 10/100BaseT(X) for Ethernet LAN 
IEEE 802.3af for Power-over-Ethernet (PoE models 
Only) 

Spread Spectrum 
and Modulation 
(typical) 

 

DSSS with DBPSK, DQPSK, CCK   

 

OFDM with BPSK, QPSK, 16QAM, 64QAM   

 

802.11b:   
CCK @ 11/5.5 Mbps   
DQPSK @ 2 Mbps   
DBPSK @ 1 Mbps   

 

802.11a/g:   
64QAM @ 54/48 Mbps   
16QAM @ 36/24 Mbps   
QPSK @ 18/12 Mbps 
BPSK @ 9/6 Mbps 

 
 
 

All manuals and user guides at all-guides.com

Содержание AirWorks AWK-1127

Страница 1: ...ghts reserved Reproduction without permission is prohibited P N 1802011270012 AWK 1127 Quick Installation Guide Moxa AirWorks Second Edition June 2014 All manuals and user guides at all guides com a l...

Страница 2: ...ting or distribution boxes The Din Rail mounting ability wide operating temperature range and IP30 housing with LED indicators make the AWK 1127 a convenient yet reliable solution for any industrial w...

Страница 3: ...PWR2 3 RS 232 console port 4 AUX antenna port 5 System LEDs PWR FAULT and STATE LEDs 6 LEDs for signal strength 7 WLAN and LAN LEDs 8 10 100BaseT X RJ45 Port 9 MAIN antenna port 10 RS 232 422 485 Seri...

Страница 4: ...Rail attachment plate to the AWK 1127 make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 Insert the top of the DIN Rail into the slot just below the stif...

Страница 5: ...m in diameter and the shafts should be less than 3 5 mm in diameter as shown in the figure at the right Do not screw the screws in all the way leave a space of about 2 mm to allow room for sliding the...

Страница 6: ...ations wiring and power wiring in the same wire conduit To avoid interference wires with different signal characteristics should be routed separately You can use the type of signal transmitted through...

Страница 7: ...terminals STEP 2 To keep the DC wires from pulling loose use a small flat blade screwdriver to tighten the wire clamp screws on the front of the terminal block connector STEP 3 Insert the plastic term...

Страница 8: ...port You may then use a console terminal program to access the AWK 1127 for console configuration Console Pinouts for 10 pin or 8 pin RJ45 10 Pin Description 8 Pin 1 2 DSR 1 3 RTS 2 4 GND 3 5 TxD 4 6...

Страница 9: ...N is transmitting data Off WLAN is not established or is not working properly LAN Green On 100 10 Mbps LAN port is active Blinking Data is being transmitted Off 100 10 Mbps LAN port is inactive TX RX...

Страница 10: ...bps Typ 16 1 5 dBm 48 Mbps Typ 16 1 5 dBm 54 Mbps 802 11a Typ 18 1 5 dBm 6 to 24 Mbps Typ 16 1 5 dBm 36 Mbps Typ 15 1 5 dBm 48 Mbps Typ 14 1 5 dBm 54 Mbps RX Sensitivity 802 11b 97 dBm 1 Mbps 94 dBm 2...

Страница 11: ...0 to 60 C 32 to 140 F Wide Temp Models 40 to 75 C 40 to 167 F Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non condensing Power Requirements Input Voltage 12 to 48 VDC...

Страница 12: ...y cause undesired operation ATTENTION Do not locate the antenna near overhead power lines or other electric light or power circuits or where it can come into contact with such circuits When installing...

Страница 13: ...69 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa...

Отзывы: