background image

  

39 

 

8

 

Maintenance and Proper 
Disposal 

8.1

 

Maintenance 

Besides charging the batteries, 

LightMove 3

 does not need any 

further maintenance. The battery capacity will decrease slowly with 
charging cycles and age. The battery can only be changed by

. Please contact us in the case when a replacement is 

necessary. 

8.2

 

Cleaning Instructions 

If you want to clean 

LightMove 3

, please note the following: 

 

Disconnect the sensor from USB cable and wrist band. 

 

Use a soft slightly moistened cloth. 

 

Take care that no humidity enters the sensor housing. 

8.3

 

Cleaning of Wrist Bands  

To clean the wrist bands please consider the following: 

 

Wash the bands by hand and not in the washing machine. 

 

Use a mild liquid detergent. 

 

Directly after washing, air -dry the bands before storing or 
using it for new measurements. 

8.4

 

Proper Disposal 

Содержание LightMove 3 10150

Страница 1: ...User Manual LightMove 3 Physical Activity and Ambient Light Sensor Bedienungsaneitung ...

Страница 2: ...re https www movisens com wp content downloads LightMove3_User_Manual pdf Frequently asked questions https www movisens com en faq movisens GmbH Augartenstraße 1 76137 Karlsruhe Germany Phone 49 721 381344 0 Fax 49 721 381344 90 Internet www movisens com E Mail support movisens com Copyright movisens GmbH ...

Страница 3: ...irements 17 6 2 Installing the Software 18 6 3 Updating the Software 19 6 4 Updating the Sensor Firmware 19 6 5 Uninstalling the Software 20 7 Handling 21 7 1 Charging the Sensor 23 7 2 Preparing a Measurement 25 7 3 Starting a Measurement 26 7 4 Attaching the Sensor to the Test Person 28 7 5 Stopping a Measurement 29 7 6 Storing Measurement Data 30 7 7 Viewing Measurement Data 34 7 8 Analyzing Da...

Страница 4: ...8 3 Cleaning of Wrist Bands 39 8 4 Proper Disposal 39 8 5 Troubleshooting 40 9 Technical Data 41 10 Legal Notes 43 10 1 Copyright 43 10 2 Disclaimer 43 10 3 Trademarks 43 ...

Страница 5: ...nt light in everyday life Please read this manual completely and thoroughly before bringing the measurement system into service In this manual you will find all information relevant to the use and maintenance of the measurement system as well as for solving problems If you have any further questions don t hesitate to call us It is our pleasure to help you Phone 49 721 381344 0 E Mail support movis...

Страница 6: ......

Страница 7: ...a a color light sensor This sensor allows the measurement of Lux the brightness measurement over a wide range darkness to sunlight color temperature measurement and light source type detection enabled by an integrated additional IR channel In addition the ambient temperature is also acquired The sensor can be configured via a PC by utilizing the Sensor Manager software included in this package Whe...

Страница 8: ...ght Illuminance lux Color temperature K In addition to the offline calculation LightMove 3 offers the possibility of live analysis of physical activity and in conjunction with movisensXS the software platform for experience sampling and the Sensor Trigger the realization of interactive ambulatory assessment strategies In live mode the following parameters can be measured calculated and transmitted...

Страница 9: ...etSedentary metLight metModerate metVigorous light red green blue clear ir These values are transmitted with 1 value per minute Additional live parameters will be available soon Tip movisens can calculate other parameters from raw data upon request ...

Страница 10: ......

Страница 11: ...of Don t use the sensor in wet environments The sensor is protected against light splashes of water Only use the LightMove 3 under the specified conditions To charge the battery of LightMove 3 only use USB standard compatible devices If LightMove 3 is used with wrist strap these have to be cleaned regularly If any problems occur by wearing the sensor e g pressure marks skin irritations or other di...

Страница 12: ......

Страница 13: ...dition to the scope of delivery 4 1 Scope of Delivery The following component is included in delivery Article Order No LightMove 3 Activity and Ambient Light Sensor Raw data acquisition Ambient Light 1 Hz 3D Acceleration 64 Hz Barometric Altitude 8 Hz Measurement duration 9 days up to 2 months with re charging live analysis of data Bluetooth Smart interface Fixation port for use with wristband inc...

Страница 14: ...cm 10129 Wrist Band Move 3 M Size M Wrist Measurement 15 to 18 cm 10130 Wrist Band Move 3 L Size L Wrist Measurement 17 to 23 cm 10131 Wrist Band Move 3 XL Size XL Wrist Measurement 20 to 28 cm 10132 USB Charger USB Charger for 110 240V 30100 USB Hub USB Hub 2 0 7 Ports 30101 Micro USB Cable 30102 Cradle Cradle with Micro USB interface 30110 ...

Страница 15: ...iture 20101 DataAnalyzer Module Sleep Single User Licence in combination with DataAnalyzer Base Algorithms for Sleep Analysis 20104 DataAnalyzer Module AmbientLight Single User Licence in combination with DataAnalyzer Base Algorithms for Ambient Light 20105 movisensXS Basic Experience Sampling for Android Bundle license for 10 000 item results usable with unlimited number of smartphones 20110 movi...

Страница 16: ... LightMove 3 sensor for the objective assessment of physical activity and ambient light movisens SensorManager software to configure and read out the sensor UnisensViewer for visualization and preprocessing of sensor data and calculated results movisens DataAnalyzer software for analysis of sensor data calculation of outcome parameters and for the creation of reports allows the offline analysis of...

Страница 17: ...d description of these components can be found in the following documents Online help for UnisensViewer www unisens org DataAnalyzer User Manual Online help movisensXS xs movisens com help Sensor Trigger User Manual ...

Страница 18: ...ooth Smart interface The sensor can be used in conjunction with a gateway or a mobile phone for live applications The Bluetooth Smart interface is activated in the default configuration of the sensor To deactivate this interface a firmware update is required see 6 4 The axes of the integrated acceleration sensor are described in the following figure ...

Страница 19: ...conds Delayed recording active Flashing green The sensor is connected to a PC or a charger The battery is fully charged Flashing blue The sensor is connected to a PC or a charger The battery is charging Flashing magenta The sensor is active and records data It is connected to a charger and charging Flashing yellow The sensor is active records data It is connected to a charger The battery is fully ...

Страница 20: ...curred Reset sensor see 8 5 If the sensor doesn t stop flashing please contact the manufacturer No LED active The sensor is inactive Combinations of red and green blinking as well as red and blue blinking are possible with the appropriate combination of the above descriptions LightMove 3 features a vibration alarm when Bluetooth is getting disconnected ...

Страница 21: ...nstallation A minimum of 300 MB free space on hard disc The delivered software consists of two programs SensorManager Program to configure the sensor to start a measurement and to download the data from the sensor UnisensViewer Program to view the stored data Option In addition to this analysis software android sensor trigger app and cloud service for experience sampling can be ordered as a comple...

Страница 22: ...Double click the file movisens_SensorManager_Setup exe The Installation runs automatically in the background After successful installation shortcuts are created in the Windows Start Menu under the entry movisens SensorManager The use of the different programs is explained in the following chapters Step 3 Double click the file UnisensViewer_Setup_Full exe The Installation runs automatically in the ...

Страница 23: ...fferent programs is explained in the DataAnalyzer User Manual 6 3 Updating the Software You need an internet connection to make an update Select Windows Start Menu movisens SensorManager Updater If a new version is available it will be downloaded and installed automatically after starting the updater software 6 4 Updating the Sensor Firmware If the SensorManager contains a sensor firmware version ...

Страница 24: ...customized sensor applications or to deactivate the Bluetooth interface You can get these firmware versions upon request from movisens To install the new firmware please start Windows Start Menu movisens SensorManager Firmware Updater You can now select the new firmware and Start the update 6 5 Uninstalling the Software The software can be uninstalled using the Windows Control Panel ...

Страница 25: ...on how to save delete and analyze data from the sensor A typical usage scenario for the assessment of data and offline analysis is shown in the following diagram The relevant software for each step is indicated on the left side of the diagram The different steps are described in further detail in the chapters indicated on the right of the diagram ...

Страница 26: ...figure Unlike the offline measurement the measurement is initiated on your mobile device The right side of the diagram illustrates the process to prepare and run a study on movisensXS To retrieve the data from the LightMove 3 you have to read out the sensor after the measurement The results of movisensXS only contain the sensor information that causes a trigger ...

Страница 27: ... 4 2 After connecting the sensor to a USB port the charging process starts immediately During charging the status LED is blinking blue If the battery is fully charged the LED is blinking green The charging process of the sensor can take up to two hours depending on the battery status of your sensor If the sensor is fully charged the battery run time during recording is 9 days Step 2 To extend the ...

Страница 28: ...f the sensor runs out of battery lifetime during a long measurement the recording of data will be stopped The measurement won t be continued even if you connect it to a charger If the sensor is discharged completely e g after a long period where it was not used it can take up to several minutes until the sensor reacts and can be identified by the computer You can control the battery status before ...

Страница 29: ...described in chapter 6 2 Step 1 Start the SensorManager by selecting Windows Startmenu movisens SensorManager SensorManager SensorManager is now searching for available sensors Step 2 Connect LightMove 3 with your PC using the cradle The software will automatically detect the device and open the following window ...

Страница 30: ...n the battery is fully charged When connecting for the first time allow up to 30 seconds for the device to be detected as it installs the driver 7 3 Starting a Measurement To start a measurement please perform the following steps Step 1 In the SensorManager software click on the Start Recording button in the lower left of the window You can see the following window Step 2 Please supply the followi...

Страница 31: ...urement by clicking the Start button You will see the following window Step 4 Please follow the instructions and remove the sensor from the PC The status LED will flash red once per second as soon as the measurement has started and data will be recorded If a delayed start was configured the LED flashes red every two seconds until the measurement starts At the end of the measurement the LED stops f...

Страница 32: ... attach the sensor to the non dominant hand of the test person At this position only simple parameters like Movement Acceleration can be measured Depending on the position of the sensor different parameters can be analyzed after the measurement The following figure and table lists the possible sensor locations supported by the analysis software DataAnalyzer and the ...

Страница 33: ...cceleration Activity class Body position Energy expenditure right left wrist 7 5 Stopping a Measurement The measurement will automatically be stopped if the configured measurement duration has passed A running measurement will also be stopped when The sensor is connect to a PC The end of the battery run time has been reached ...

Страница 34: ...e sensor nor in the SensorManager software That allows you to have a sustainable database with all the raw data of your study that can be used with future studies and with future algorithms To store recorded measurement data on the PC do the following steps Step 1 Start the SensorManager by selecting Windows Start menu movisens SensorManager SensorManager Step 2 Connect LightMove 3 to the PC using...

Страница 35: ...31 7 Step 3 Click on Save Data You will see the following window ...

Страница 36: ...click the button after the text input field If the measurement data shall be further processed with the movisens DataAnalyzer the additional information about the person and the sensor location is mandatory Step 5 Finally click on Save data The measurement data will be stored either in the unisens format or as a csv file Unisens is an open data format for multi sensor data You can find further inf...

Страница 37: ...l If you select to store data in unisens format the following files will be generated movementacceleration bin is the result of the live analysis on the sensor the other bin files are the raw data of the other measurement parameters If you select to store data in csv format the following files will be generated ...

Страница 38: ... directly start data analysis and generate reports by clicking on Analyze data You can find more information in the DataAnalyzer User Manual 7 7 Viewing Measurement Data To view recorded measurements click on Show data directly after storing the data Tip When storing data as csv file you have to take into account that the size of the data file doesn t exceed the maximum size of the program you wan...

Страница 39: ...UnisensViewer A first preprocessing of the data can be done with UnisensViewer You can crop your signal to the desired time set markers and annotate artefacts Details can be found in the online help of UnisensViewer Tip Directly after storing the data you should check if the measurement is complete and correct You can check visually if all signals are recorded for the full measurement duration and...

Страница 40: ...36 You directly start the analysis of the data with DataAnalyzer by clicking the Analyze Data button Tip Before changing the data of your study be sure to have a copy of your raw data ...

Страница 41: ...ary parameters from your physiologic measurement data create summaries and reports DataAnalyzer is capable of batch processing complete measurement data bases After a measurement was selected all possible analysis outputs secondary parameters and reports are shown The list of analysis outputs is dependent on your licensed modules and the data contained in your measurement You can now select the de...

Страница 42: ...files for each measurement signal and secondary parameter Secondary parameters are stored as a csv file within the unisens data set and can also be processed e g with Microsoft Excel or SPSS Tip can also analyze your raw data and generate reports according to your needs If you have any further questions please do not hesitate to contact us ...

Страница 43: ...ry 8 2 Cleaning Instructions If you want to clean LightMove 3 please note the following Disconnect the sensor from USB cable and wrist band Use a soft slightly moistened cloth Take care that no humidity enters the sensor housing 8 3 Cleaning of Wrist Bands To clean the wrist bands please consider the following Wash the bands by hand and not in the washing machine Use a mild liquid detergent Direct...

Страница 44: ...ions Sensor is not blinking when connected If battery is empty it can take 30 seconds or more for the LED to start blinking Sensor is not found by sensor manager Reset sensor This is found in the start menu under the movisens Sensor Manager folder The LED will flash all colours blue red green when it is reset Flashing Red 3 times per second An error occurred Reset sensor If the sensor doesn t stop...

Страница 45: ... 5mm Internal sensors 3D acceleration sensor Measurement range 8 g Noise 4 mg Output rate 64 Hz Pressure sensor Measurement range 300 1000 hPa Noise 0 03 hPa Output rate 1 Hz Ambient Light Sensor Number of channels 5 red green blue clear ir Measurement range 0 45 000 lux Resolution Up to 0 011 lux at low end Output rate 1 Hz Indicators LED 3 color operation and charging status Vibration alarm Blue...

Страница 46: ...42 Environmental conditions Temperature 20 C to 60 C 0 C to 45 C during charging Humidity 0 to 75 RH relative humidity Atmospheric pressure 300 to 1100 hPa absolute ...

Страница 47: ...ens makes no representations or warranties with respect to this manual or with respect to the products described herein movisens shall not be liable for any damages losses costs or expenses direct indirect or incidental consequential or special arising out of or related to the use of this material or the products described herein The activity sensor LightMove 3 is not a medical device and is not i...

Страница 48: ...Bedienungsaneitung movisens GmbH Augartenstraße 1 76137 Karlsruhe Germany Tel 49 721 381344 0 Fax 49 721 381344 90 support movisens com http www movisens com ...

Отзывы: