9
Manual
FUMEX ASEM
65/85/125
Manual
MOVEX ASEM
65/85/125
4.3.7 Installation
4.3.7.1 Electrical installation
A lockable safety switch (e.g. SSB 750) must be used for
the input power supply so that safe servicing can be
carried out.
The motor is supplied with 230 V 1N~ and installed
together with control devices according to the circuit
diagram (see section
10.2 Circuit diagram electronics
4.3.8 Adjusting the end positions
Incorrectly set end positions can cause serio-
us personal injuries and property damage.
As standard, hose reels including hoses
are supplied prepared for mounting on the
ceiling.
The final position for retraction and roll-
out varies and is adjusted by the customer.
When adjusting end positions, consider the
selected mounting method according to
.
1.
Remove the screws and open the cover; see
.
Fig. 12
5 Commissioning
5.1 Start-up
Any faults must be rectified before turning
on the power.
1.
Switch on the power supply.
2.
Check the operation of the machine. White button
for retraction, black button for roll-out.
6 Operation
Only equipment intended and approved for
the product may be connected to the pro-
duct, otherwise the operation of the product
cannot be guaranteed.
When retracting and unrolling the hose, do
not leave the hose/nozzle in a position where
there is a risk of personal injury.
If the motor overheats, a temperature
guard will switch on until the motor returns
to the correct working temperature. Normally
within 4–5 minutes.
In the event of a power failure, disconnect
the motor to rotate the drum manually. See
section
.
2.
Adjust end positions by turning the retraction and
roll-out wheels (3, 4,
).
3.
When the final positions are set as desired, refit the
cover on the motor.
4.
The hose reel is now ready for operation.
Содержание ASEM 125