4.3.7 Installation

4.3.7.1 Electrical installation

A lockable safety switch (e.g. SSB 750) must be used for 
the input power supply so that safe servicing can be 
carried out. 
The motor is supplied with 230 V 1N~ and installed 
together with control devices according to the circuit 
diagram (see section 

10.2 Circuit diagram electronics

).

4.3.8 Adjusting the end positions

Incorrectly set end positions can cause serio-
us personal injuries and property damage.

As standard, hose reels including hoses 
are supplied prepared for mounting on the 
ceiling.
The final position for retraction and roll-
out varies and is adjusted by the customer. 
When adjusting end positions, consider the 
selected mounting method according to 

Fig. 

3

 an

Fig. 4

.

1. 

Remove the screws and open the cover; se

Fig. 12

.

Fig. 12 

5 Commissioning

5.1 Start-up

Any faults must be rectified before turning 
on the power.

1. 

Switch on the power supply.

2. 

Check the operation of the machine. White button 
for retraction, black button for roll-out.

6 Operation

Only equipment intended and approved for 
the product may be connected to the pro-
duct, otherwise the operation of the product 
cannot be guaranteed.
When retracting and unrolling the hose, do 
not leave the hose/nozzle in a position where 
there is a risk of personal injury.

If the motor overheats, a temperature  
guard will switch on until the motor returns 
to the correct working temperature. Normally 
within 4–5 minutes.
In the event of a power failure, disconnect 
the motor to rotate the drum manually. See 
section 

4.3.4 Declutching the motor

.

2. 

Adjust end positions by turning the retraction and 
roll-out wheels (3, 4

Fig. 7

).

3. 

When the final positions are set as desired, refit the 
cover on the motor.

4. 

The hose reel is now ready for operation.

Содержание ASEM 125

Страница 1: ...ASEM 65 85 125 Manual...

Страница 2: ...11 Accessories 14 12 Notes 16 TABEL OF CONTENTS 1 Introduction 3 1 1 The manual 3 1 2 Declaration 3 1 3 Warranty 3 1 4 Manufacturer 3 2 Safety 4 2 1 General 4 2 2 Protective equipment 4 2 3 General wa...

Страница 3: ...CE certification being voided The warranty period is one year from the date of pur chase and covers the product and its constituent parts All manufacturing defects are covered by the warranty MOVEX r...

Страница 4: ...explosive environment or to extract dust and gases in explosive concentrations All work on the machine must be carried out by certified and authorised personnel For maintenance work where contact with...

Страница 5: ...85 125 is a motorised hose reel intended for the evacuation of exhaust gases 3 4 Design See Fig 2 1 Bracket 2 Beam 3 Duct connection 4 Drum 5 Hose 6 Motor 7 Declutching system 8 Contact safety device...

Страница 6: ...installa tions For electrical installation see Section 10 2 Circuit diagram electronics 4 3 Assembly installation National rules and regulations must always be adhered to during assembly work 4 3 1 Un...

Страница 7: ...tment of end position for roll out Rotate the drum counterclockwise as viewed from the motor side until the roll out wheel 3 Fig 7 is obstructed by the stop clip 1 This is indicated by a rattling soun...

Страница 8: ...Release motor disconnect switch and refit the cover 11 The hose reel is now ready for mounting and installation 4 3 6 Mounting the hose reel Fasteners used to mount the hose reel on the ceiling or wa...

Страница 9: ...crews and open the cover see Fig 12 Fig 12 5 Commissioning 5 1 Start up Any faults must be rectified before turning on the power 1 Switch on the power supply 2 Check the operation of the machine White...

Страница 10: ...enance schedule TROUBLESHOOTING GUIDE Symptom Possible cause Recommended action 1 The hose does not stop in the correct position Incorrect end positions have been set Adjust the end positions see sect...

Страница 11: ...ical information 10 1 Technical data Dimensions inch See Fig 13 Voltage 115 V 1N Frequency 60 Hz Current 3 3 A Enclosure class IPX4 Speed 12 rpm Torque 855 IN LBS Temperature limits Operating temperat...

Страница 12: ...N PE MA1 M Brown Black Blue ASEM RADIO G Y L N L N N Manual MOVEX ASEM 65 85 125 10 2 Circuit diagram electronics 10 2 1 ASEM 1 ASEM 2 10 2 2 ASEM Radio 1 3 2 4 SSB 750 120 V 1N L1 N PE MA1 M Red Blac...

Страница 13: ...13 Manual FUMEX ASEM 65 85 125 1 2 3 4 5 6 7 8 9 10 11 12 17 16 15 14 13 21 20 19 18 Manual MOVEX ASEM 65 85 125 10 3 Exploded view drawing...

Страница 14: ...ndicator that shows whether the damper is open or closed ASES is an energy sa ving accessory Combine with fan pressure control to further optimise the system AESM 100 125 150 Hose installation kit wit...

Страница 15: ...injuries ASB Swing arm for hose reel Includes installation kit hose and pipe parts ASB 1960 ASB 4300 ASB 6300 Length 6 ft Length 14 ft Length 21 ft Weight 97 lb Weight 154 lb Weight 198 lb ASEM RADIO...

Страница 16: ...XTRACTION ARMS VEHICLE EXHAUST EXTRACTION FANS FILTERS CURTAINS CONTROLS 12 Notes 104 Commerce Drive Northampton PA 18067 USA Tel 610 440 0478 Fax 610 440 0480 Email info movexinc com www movexinc com...

Отзывы: