Other Operations
List of Function Settings
BLG-BC1 Series Operating Instructions
Corporate Headquarters:
1080 North 11th Street, San Jose, CA 95112 Phone: (408) 292-2214 Fax: (408) 292-2733
www.mountztorque.com
Page 5
The count is to be returned to the default value during
the screw fastening operation.
Pressing the F3 button for 2 seconds or more, resets
the screw fastening count value.
How to check the Screw Counter Timer: set time
When the screw is fastened for the time period (seconds)
set using the counter timer:
- For correct operation, the buzzer sounds once.
- For incorrect operation, the buzzer does not sound.
When the buzzer does not sound, increase the set value
gradually and adjust it so that the buzzer sounds once.
Display
Setting Function
<Default Value>
Symbol
Setting Description
(1)
Counter ON/OFF Setting
: When selected, the counter function is available.
: When selected, it is used as a normal driver.
(2)
Count
The screw fastening count value is set.
Setting Range: 1 to 99
(3)
Count Timer
This function is used to prevent the count for double
tightening operations such as check fastening or
retightening.
Set the operation time while the check fastening is
performed for the tightened screw.
Setting Range: 0.00 to 0.99 seconds
Note: When the screw tightening operation is performed
during this setting and the judgment result is normal,
the buzzer sounds once.
(4)
Work - Reset - Timer
The buzzer sound time period after the work is
completed is set.
Setting Range: 0.0 to 3.9 seconds
Note: Set it based on the reverse count timer set value.
(5)
Reverse Count Timer
The time period until the reverse count is performed is
set. Set the work reset timer operation time based on
the time period up to when the reverse count is per-
formed.
Setting Range: 0.1 to 1.0 seconds
Note: It is available when the “Reverse Count Enable”
has been set in the system setting.