BLG-BC1 Series Operating Instructions
Corporate Headquarters:
1080 North 11th Street, San Jose, CA 95112 Phone: (408) 292-2214 Fax: (408) 292-2733
www.mountztorque.com
Page 4
Screw Counter Display
Screw Count Display Section/Set Value Display
Section:
In the normal mode, the screw fastening count set value is
displayed first. After starting the count, the remaining
screw fastening count is displayed.
The count decreases with each screw fastening operation
and the remaining screw fastening count is displayed.
Function Display Section:
The symbol corresponding to the set item is displayed in
the setting mode. (See page 5 for the list of setting
functions).
F1 Button:
When this button is pressed for more than 2 seconds in the normal mode, the mode is changed to the “setting mode”.
This button is used for selecting the function in the “setting mode”.
When this button is pressed for more than 2 seconds in the “setting mode”, the buzzer sounds twice and the mode is
changed to the normal mode.
F2 & F3 Buttons:
Using these buttons, the set value can be changed in the function settings.
Some set values are limited depending on the function that is being set.
Pass Light (Green):
When the screw fastening result is “OK”, the green LED lamp turns ON.
Fail Light (Red):
When the screw fastening result is NG (No Good), the red LED lamp turns ON.
Note!
When the lever switch is turned ON, the lamp turns OFF (reset).
When this unit is used in combination with the existing HIOS external screw counter, the driver counter does not synchro-
nized with the external screw counter. So, use them based on the external counter function. Otherwise, turn off the driver’s
counting function before use.
When the output setting for Power HI/LOW is changed, the driver speed changes. In such cases, pay attention to the counter
timer set value and reverse counter timer set value.
Only the T-30BL or the T-70BL power units (transformers) can be used with this driver. Do not connect it to any other power
unit.
F2 Button
F1 Button
F3 Button
Fail Light (Red)
Pass Light (Green)
Function Display Section
Screw Count/Function
Mode Display