14.
Parameter List
Parameter
Min. value
Max. value
Default
Digits
Decimal
positions
Serial Code
*Operand
-99 999
99 999
10 000
+/- 5
4
00
/Operand
1
99 999
10 000
5
4
01
+/- Operand
-100 000 000 100 000 000
0
+/- 9
0
02
Teach Minimum A
-100 000 000 100 000 000
0
+/- 9
0
03
Teach Maximum A
-100 000 000 100 000 000
10 000
+/- 9
0
04
Factor A
1
99 999
10 000
5
4
05
Factor B
1
99 999
10 000
5
4
06
Output
Mode 0 3 0
1
0
07
Linearization
Mode
0 2 0
1
0
08
¼ Edge Mode
0
1
0
1
0
09
AB
Mode
0 2 0
1
0
10
Reset Mode
0
4
0
1
0
11
Reset Value
-100.000 000 100 000 000
0
+/- 9
0
12
Round Loop
0
1 000 000
0
7
0
13
Power up Mode
0
1
0
1
14
P1 (x)
-100 000
100 000
100 000
+/- 6
3
A0
P1 (y)
-100 000
100 000
100 000
+/- 6
3
A1
P2 (x)
-100 000
100 000
100 000
+/- 6
3
A2
P2 (y)...
-100 000
100 000
100 000
+/- 6
3
A3...(A9)...(B0)
P16 (x)
-100 000
100 000
100 000
+/- 6
3
D0
P16 (y)
-100 000
100 000
100 000
+/- 6
3
D1
Direction
0 1 0
1
0
46
Analog Offset
-99
99
0
+/- 2
0
47
Analog Gain
0
10 000
1 000
5
0
48
Unit Number
0
99
11
2
0
90
Serial
Rate
0 6 0
1
0
91
Serial
Format 0 9 0
1
0
92
Serial
Protocol 0 1 0
1
0
30
Serial Timer
5
99 999
100
5
3
31
Register Code
0
19
0
2
0
32
Backup Encoder A
-100 000 000 +100 000 000
0 +/-
9
0 33
Backup Encoder B
-100 000 000 +100 000 000
0 +/-
9
0 34
Backup Rest A
-10 000
+10 000
0
+/- 5
0
35
Backup Rest B
-10 000
+10 000
0
+/- 5
0
36