Page 1 / 26 

ZU 251 

 

Incremental Counter Module 

With Analogue Output and Serial Interface 

 

 

 

 

Counter suitable for quadrature signals (A/B, 90º) as well as single channel inputs 

 

Counting inputs selectable to TTL/ RS422 format or to HTL / 10-30 volts format 

 

Maximum counting frequency 500 kHz 

 

Analogue o/-10 V, 0-20 mA and 4-20 mA, polarity following the sign of the 
internal counter 

 

Analogue conversion time 1 msec only 

 

RS 232 and RS 485 interfaces for serial readout of the counter 

 

Also suitable for conversion of the sum or the difference of two separate counts 

 

Facility for free linearization of the analogue output by 16 interpolation points 

 

Easy to set up by TEACH procedure, or by PC and Windows software 

 
 

 

Operating Instructions 

 

ELEKTRO-TRADING   sp. z o.o

Tel.        +48 (0-32) 734-55-72
Tel/

Fax

 

 +4

8

 (0

-32

)

 

7

34-55-70

E-Mail [email protected]
http://www.elektro-trading.com.pl

Содержание ZU 251 Series

Страница 1: ...and 4 20 mA polarity following the sign of the internal counter Analogue conversion time 1 msec only RS 232 and RS 485 interfaces for serial readout of the counter Also suitable for conversion of the...

Страница 2: ...nd also all country specific and application specific safety standards When this unit is used with applications where failure or maloperation could cause damage to a machine or hazard to the operating...

Страница 3: ...rocedure 11 5 1 Operation as single channel counter without direction signal or as positional counter with direction signal 12 5 2 Operation as a summing or differential counter with two independent i...

Страница 4: ...erial a Up down count with quadrature input A B 90 The polarity of the analogue output and the sign of the serial data depend on the sign of the actual counting result b Single channel impulses on cha...

Страница 5: ...nnel sources like proximities or photocells providing HTL output and PNP or NPN or NAMUR characteristics Single channel sources with TTL RS422 output providing both signal and inverted signal differen...

Страница 6: ...of the unit is approx 150 mA see specifications 1 2 3 4 5 6 7 8 9 10 11 12 Analogue out 10V TTL Input B HTL n c TTL Input B HTL Input B Analogue GND 18 30 VDC typ 200 mA GND 0 20mA 4 20mA out TTL Inp...

Страница 7: ...second counting input For use of sensors providing 2 wire NAMUR characteristics Set the inputs to HTL and NPN Connect the positive wire of the sensor to the corresponding input and the negative wire t...

Страница 8: ...variables by PC according to need 5 4 3 2 1 9 8 7 6 GND int TxD RxD RS232 5V T T R R RS485 Sub D 9 female on unit site 5 4 3 2 1 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 9 8 7 6 GND TxD R...

Страница 9: ...26 4 DIL switch settings The DIL switch located on the top site of the unit provides customer specific settings of the desired operation modes Changes of the switch settings will become active only a...

Страница 10: ...22 RS 232 RS 485 1 2 3 4 5 6 7 8 The switch settings shown in the example are suitable for a quadrature encoder with HTL and NPN characteristics The power down memory is switched off and the serial li...

Страница 11: ...cted a pulse on input A The LED will be OFF when no input pulse has been detected When you press the TEACH button once more you can also check input B if applicable With use of mode A B and two indepe...

Страница 12: ...ase set the counter to the desired state or move the encoder to the desired position and reset the counter to zero Then press the Teach button again This stores your minimum counter definition The LED...

Страница 13: ...according to the ISO 1745 standard Details about the protocol can be found in our document SERPRO doc available for download under www motrona com The following register codes are available for reado...

Страница 14: ...ection 3 5 of this manual Make sure the cable only uses pins 2 3 and 5 Pins 2 and 3 must be crossed Run the OS3 x software and you will see the following screen If your text and color fields remain em...

Страница 15: ...ardware The boxes in the OUTPUTS field provide information about the state of the unit where Status A and Status B are especially useful to check the counting inputs Status A is lit when a counting pu...

Страница 16: ...nimum and TEACH maximum settings Operand Readout from 8 Measuring result in of fullscale x xOperand Operand General Setting Teach Minimum Teach Maximum This couple of settings define your minimum and...

Страница 17: ...ting with use of quadrature A B input allows simple count x1 or full quadrature count x4 by either accepting rising edges from input A only or all rising and falling edges from inputs A and B 0 simple...

Страница 18: ...o 000 000 provides counting over the full range Power up Mode Sets the action of the counter upon power up 0 Loads the previous value from power down memory 1 sets counter to zero Set Up Settings Anal...

Страница 19: ...even 1 1 7 even 2 2 7 odd 1 3 7 odd 2 4 7 none 1 5 7 none 2 6 8 even 1 7 8 odd 1 8 8 none 1 9 8 none 2 Serial Format Factory setting Protocol Setting The serial port of the unit can operate in either...

Страница 20: ...tarts with the register value directly This allows a little faster transmission because of the shorter transmission time Unit No Serial Protocol 0 1 1 X X X X X X LF CR Serial Protocol 1 X X X X X X L...

Страница 21: ...Now enter the attached values to registers P1 y to P16 y These are the values that the analogue output will generate instead of the x values Example the value set to register P2 y will substitute ori...

Страница 22: ...oscope For this select TOOLS then TEST and there Analogue Voltage Function The unit will now simulate a repeating counting cycle over the full range and generate the analogue signal accordingly When y...

Страница 23: ...26 11 Test Functions When you select TEST from the TOOLS menu you are able to verify the following data by clicking to the corresponding field Actual counter value DIL switch settings Internal supply...

Страница 24: ...ZU25102A_e DOC Mrz 08 Page 24 26 12 Dimensions 74 mm 2 913 91mm 3 583 40 mm 1 575 79 mm 3 110 Front view Side view Top view...

Страница 25: ...A 4 20 mA 270 Ohm Step width of analogue outputs 1 25 mV 2 5 A Analogue resolution 14 bits 10V 20mA 10V 20mA Accuracy of analogue output 0 1 1 digit Response time counter analogue normal operation app...

Страница 26: ...0 000 000 100 000 000 0 9 0 12 Round Loop 0 1 000 000 0 7 0 13 Power up Mode 0 1 0 1 14 P1 x 100 000 100 000 100 000 6 3 A0 P1 y 100 000 100 000 100 000 6 3 A1 P2 x 100 000 100 000 100 000 6 3 A2 P2 y...

Отзывы: