Motrona SV211 Скачать руководство пользователя страница 9

 

Sv211_01c_oi_e.doc / Apr-16 

 

Page 9 / 9 

 

6.

 

Technical Specifications 

 

Power supply: 

Input voltage: 
Protection: 
Ripple: 
Consumption: 
Connections: 

17 … 30 VDC, galvanically isolated 
reverse polarity protection 

 10 % at 24 VDC 

approx. 70 mA (unloaded) 
screw terminal, 1.5 mm² / AWG 16 

Encoder supply: 

Output voltage: 
Output current: 
Connections: 

5.2 VDC  (or according to external input voltage) 
max. 150 mA  
screw terminal, 1.5 mm² / AWG 16 

SinCos inputs: 

Amplitude: 
Offset: 
Channels: 
Frequency: 
Terminating resistors: 
Connections: 

min. 0.8 Vpp … max.1.2 Vpp 
approx. 2 … 3 V 
SIN+, SIN-, COS+, COS-, REF+, REF-  
max. 500 kHz 
120 Ohm (already integrated in the unit) 
SUB-D connector (male),  9-pin 

SinCos outputs: 

Number of outputs:  
Amplitude: 
Offset: 
Channels: 
Terminating resistors: 
Connections: 


min. 0.8 Vpp … max.1.2 Vpp 
approx. 2.5 V 
SIN+, SIN-, COS+, COS-, REF+, REF-  
120 Ohm (must be equipped with the target device) 
SUB-D connector (female), 9-pin 

Housing: 

Material: 
Mounting: 
Dimensions (w x h x d): 
Protection class: 
Weight: 

plastic 
35 mm top hat rail (according to EN 60715) 
22.5 x 102 x 102 mm / 0.886 x 4.016 x 4.016 inch  
IP20 
approx. 100 g 

Ambient temperature: 

Operation: 
Storage: 

   0 °C … +45 °C  / +32 … +113 °F (not condensing) 
-25 °C … +70 °C  / -13 … +158 °F (not condensing) 

Failure rate: 

MTBF in years: 

94.2 a (long-term usage at 60 °C / 140 °F ) 

Conformity & standards:  EMC 2004/108/EC: 

Guideline 2011/65/EU: 

EN 61000-6-2, EN 61000-6-3, EN 61000-6-4 
RoHS-conform 

 

Содержание SV211

Страница 1: ...ut 3 sin cos 1Vpp Out 2 sin cos 1Vpp Out 4 sin cos 1Vpp SV 211 Interface type SV211 SinCos signal splitter with 4 SinCos outputs Product features Encoder inputs SIN SIN COS COS REF REF with 1 Vpp form...

Страница 2: ...modification usage or publication in other electronic and printed media as well as in the internet requires prior written authorization by motrona GmbH Table of Contents 1 Safety Instructions and Res...

Страница 3: ...e right to modify the hardware software or operation manual at any time and without prior notice Therefore there might be minor differences between the unit and the descriptions in operation manual Th...

Страница 4: ...sections for wiring are described in the technical specifications see chapter 6 Before first start up it must be ensured that all connections and wires are firmly seated and secured in the screw termi...

Страница 5: ...at is available as on the input site including a reference impulse if available on the input site All SinCos signals use the differential 1 Vpp format which is most common with industrial SinCos encod...

Страница 6: ...w LED Encoder supply 2 1 GND Sub D 9 female Output 4 sin cos 1 Vpp Sub D 9 female Output 2 sin cos 1 Vpp 1 2 1 DGND X4 3 1 Power and Encoder Supply X6 X7 The unit operates from a DC power from 17 30 v...

Страница 7: ...sin sin GND ref ref cos 1 2 3 4 5 9 8 6 7 nc 1 2 X6 Encoder supply GND 5 2 V Vcc int X5 All differential lines SIN SIN COS COS REF REF are internally terminated by 120 ohms load resistors 3 3 The Sine...

Страница 8: ...lit whenever the power supply of the unit is on The yellow LED indicates the availability of the encoder supply 5 V The yellow LED is lit whenever the supply is available 5 Dimensions 102 4 016 91 3 5...

Страница 9: ...Ohm already integrated in the unit SUB D connector male 9 pin SinCos outputs Number of outputs Amplitude Offset Channels Terminating resistors Connections 4 min 0 8 Vpp max 1 2 Vpp approx 2 5 V SIN S...

Отзывы: