1.

 

Safety Instructions and Responsibility  

1.1

 

General Safety Instructions 

This operation manual is a significant component of the unit and includes important rules and 
hints about the installation, function and usage. Non-observance can result in damage and/or 
impairment of the functions to the unit or the machine or even in injury to persons using the 
equipment!  

 

Please read the following instructions carefully before operating the device and observe all 
safety and warning instructions! Keep the manual for later use.  

 

A pertinent qualification of the respective staff is a fundamental requirement in order to use 
these manual. The unit must be installed, connected and put into operation by a qualified 
electrician. 

 

Liability exclusion: The manufacturer is not liable for personal injury and/or damage to property 
and for consequential damage, due to incorrect handling, installation and operation. Further 
claims, due to errors in the operation manual as well as misinterpretations are excluded from 
liability. 

 

In addition the manufacturer reserve the right to modify the hardware, software or operation 
manual at any time and without prior notice. Therefore, there might be minor differences 
between the unit and the descriptions in operation manual. 

 

The raiser respectively positioner is exclusively responsible for the safety of the system and 
equipment where the unit will be integrated.  

 

During installation or maintenance all general and also all country- and application-specific 
safety rules and standards must be observed.  

 

If the device is used in processes, where a failure or faulty operation could damage the system 
or injure persons, appropriate precautions to avoid such consequences must be taken. 
 

1.2

 

Use according to the intended purpose 

The unit is intended exclusively for use in industrial machines, constructions and systems. Non-
conforming usage does not correspond to the provisions and lies within the sole responsibility 
of the user. The manufacturer is not liable for damages which has arisen through unsuitable 
and improper use.  

 

Please note that device may only be installed in proper form and used in a technically perfect 
condition - in accordance to the technical specifications (see chapter 

6

). The device is not 

suitable for operation in explosion-proof areas or areas which are excluded by the EN 61010-1 
standard. 
 

Содержание SV211

Страница 1: ...ut 3 sin cos 1Vpp Out 2 sin cos 1Vpp Out 4 sin cos 1Vpp SV 211 Interface type SV211 SinCos signal splitter with 4 SinCos outputs Product features Encoder inputs SIN SIN COS COS REF REF with 1 Vpp form...

Страница 2: ...modification usage or publication in other electronic and printed media as well as in the internet requires prior written authorization by motrona GmbH Table of Contents 1 Safety Instructions and Res...

Страница 3: ...e right to modify the hardware software or operation manual at any time and without prior notice Therefore there might be minor differences between the unit and the descriptions in operation manual Th...

Страница 4: ...sections for wiring are described in the technical specifications see chapter 6 Before first start up it must be ensured that all connections and wires are firmly seated and secured in the screw termi...

Страница 5: ...at is available as on the input site including a reference impulse if available on the input site All SinCos signals use the differential 1 Vpp format which is most common with industrial SinCos encod...

Страница 6: ...w LED Encoder supply 2 1 GND Sub D 9 female Output 4 sin cos 1 Vpp Sub D 9 female Output 2 sin cos 1 Vpp 1 2 1 DGND X4 3 1 Power and Encoder Supply X6 X7 The unit operates from a DC power from 17 30 v...

Страница 7: ...sin sin GND ref ref cos 1 2 3 4 5 9 8 6 7 nc 1 2 X6 Encoder supply GND 5 2 V Vcc int X5 All differential lines SIN SIN COS COS REF REF are internally terminated by 120 ohms load resistors 3 3 The Sine...

Страница 8: ...lit whenever the power supply of the unit is on The yellow LED indicates the availability of the encoder supply 5 V The yellow LED is lit whenever the supply is available 5 Dimensions 102 4 016 91 3 5...

Страница 9: ...Ohm already integrated in the unit SUB D connector male 9 pin SinCos outputs Number of outputs Amplitude Offset Channels Terminating resistors Connections 4 min 0 8 Vpp max 1 2 Vpp approx 2 5 V SIN S...

Отзывы: