Safety Instructions and Responsibility  

1.1.

 

General Safety Instructions 

This operation manual is a significant component of the unit and includes important rules and 
hints about the installation, function and usage. Non-observance can result in damage and/or 
impairment of the functions to the unit or the machine or even in injury to persons using the 
equipment!  

 

Please read the following instructions carefully before operating the device and observe all 
safety and warning instructions! Keep the manual for later use.  

 

A pertinent qualification of the respective staff is a fundamental requirement in order to use 
these manual. The unit must be installed, connected and put into operation by a qualified 
electrician. 

 

Liability exclusion: The manufacturer is not liable for personal injury and/or damage to property 
and for consequential damage, due to incorrect handling, installation and operation. Further 
claims, due to errors in the operation manual as well as misinterpretations are excluded from 
liability. 

 

In addition the manufacturer reserve the right to modify the hardware, software or operation 
manual at any time and without prior notice. Therefore, there might be minor differences 
between the unit and the descriptions in operation manual. 

 

The raiser respectively positioner is exclusively responsible for the safety of the system and 
equipment where the unit will be integrated.  

 

During installation or maintenance all general and also all country- and application-specific 
safety rules and standards must be observed.  

 

If the device is used in processes, where a failure or faulty operation could damage the system 
or injure persons, appropriate precautions to avoid such consequences must be taken. 
 

1.2.

 

Use according to the intended purpose 

The unit is intended exclusively for use in industrial machines, constructions and systems. Non-
conforming usage does not correspond to the provisions and lies within the sole responsibility 
of the user. The manufacturer is not liable for damages which has arisen through unsuitable 
and improper use.  

 

Please note that device may only be installed in proper form and used in a technically perfect 
condition (in accordance to the Technical Specifications). The device is not suitable for 
operation in explosion-proof areas or areas which are excluded by the EN 61010-1 standard. 
 

Содержание PU 210

Страница 1: ...Z and A B Z likewise adjustable to either RS422 format or TTL level or HTL 10 30V level Potential separation between input and output Conversion of a A B quadrature direction signal to a static direct...

Страница 2: ...cations and Design updates Table of Contents 1 Safety Instructions and Responsibility 3 1 1 General Safety Instructions 3 1 2 Use according to the intended purpose 3 1 3 Installation 4 1 4 Cleaning Ma...

Страница 3: ...erve the right to modify the hardware software or operation manual at any time and without prior notice Therefore there might be minor differences between the unit and the descriptions in operation ma...

Страница 4: ...cross sections for wiring are described in the Technical Specifications Before first start up it must be ensured that all connections and wires are firmly seated and secured in the screw terminals Al...

Страница 5: ...n the power supply voltage 5 to 30 volts DC Inputs and outputs are isolated via inductive high speed couplers All signals can be connected alternatively via SUB D connectors or by parallel screw termi...

Страница 6: ...op approx 1 5 volts i e 24 VDC power supply will result in a 22 5 V output swing The supply voltage can either be applied to the screw terminals marked GND and VIN on terminal strip X4 or also to the...

Страница 7: ...erted signal must be connected A A B B Z Z Acceptable input level of differential signals 3 30 volts Setting of the input format is separately for each of the encoder channels according to above indic...

Страница 8: ...nd are only conditionally suitable for signal transmissions under industrial EMC environment With standard applications please never touch the DIL switch hidden behind the front plate 4 2 Output level...

Страница 9: ...re only relevant with single channel input signals input A alone or A with B as a static direction information when this information needs to be converted into a quadrature A B format at the output In...

Страница 10: ...Pu21003b_oi_e doc Apr 16 Page 10 11 5 Dimensions 102 4 016 91 3 583 82 5 3 248 102 4 016 22 5 0 886 1 2 3 4 5 6 7 8 OFF ON 1 2 3 4 5 6 7 8 OFF ON Side view Top view Front view 82 5...

Страница 11: ...e 9 pin Incremental outputs Number of outputs Signal level Channels Output current Output circuit Signal propagation delay Connections 1 3 5 28 5 V A A B B Z Z max 30 mA per output Push Pull approx 60...

Отзывы: