background image

Pu204_02c_oi_e.doc / Apr-16 

 

Page 3 / 10 

1.

 

Safety Instructions and Responsibility 

1.1

 

General Safety Instructions 

This operation manual is a significant component of the unit and includes important rules and 
hints about the installation, function and usage. Non-observance can result in damage and/or 
impairment of the functions to the unit or the machine or even in injury to persons using the 
equipment!  

 

Please read the following instructions carefully before operating the device and observe all 
safety and warning instructions! Keep the manual for later use.  

 

A pertinent qualification of the respective staff is a fundamental requirement in order to use 
these manual. The unit must be installed, connected and put into operation by a qualified 
electrician. 

 

Liability exclusion: The manufacturer is not liable for personal injury and/or damage to property 
and for consequential damage, due to incorrect handling, installation and operation. Further 
claims, due to errors in the operation manual as well as misinterpretations are excluded from 
liability. 

 

In addition the manufacturer reserve the right to modify the hardware, software or operation 
manual at any time and without prior notice. Therefore, there might be minor differences 
between the unit and the descriptions in operation manual. 

 

The raiser respectively positioner is exclusively responsible for the safety of the system and 
equipment where the unit will be integrated.  

 

During installation or maintenance all general and also all country- and application-specific 
safety rules and standards must be observed.  

 

If the device is used in processes, where a failure or faulty operation could damage the system 
or injure persons, appropriate precautions to avoid such consequences must be taken. 
 

1.2

 

Use according to the intended purpose 

The unit is intended exclusively for use in industrial machines, constructions and systems. Non-
conforming usage does not correspond to the provisions and lies within the sole responsibility 
of the user. The manufacturer is not liable for damages which has arisen through unsuitable 
and improper use.  

 

Please note that device may only be installed in proper form and used in a technically perfect 
condition - in accordance to the Technical Specifications (see chapter 7). The device is not 
suitable for operation in explosion-proof areas or areas which are excluded by the EN 61010-1 
standard. 
 

Содержание PU 204

Страница 1: ...hout potential separation Product Features Converts TTL RS422 signals A A B B Z Z to HTL with 10 30 VDC level Generates also a static HIGH LOW direction signal or separate direction pulses from a dire...

Страница 2: ...motrona GmbH Table of Contents 1 Safety Instructions and Responsibility 3 1 1 General Safety Instructions 3 1 2 Use according to the intended purpose 3 1 3 Installation 4 1 4 Cleaning Maintenance and...

Страница 3: ...e right to modify the hardware software or operation manual at any time and without prior notice Therefore there might be minor differences between the unit and the descriptions in operation manual Th...

Страница 4: ...sections for wiring are described in the Technical Specifications see chapter 7 Before first start up it must be ensured that all connections and wires are firmly seated and secured in the screw term...

Страница 5: ...a TTL or RS422 format to a 10 30 V HTL format At same time the unit is suitable to convert the information of direction from the quadrature format to other usual standards like shown in the pulse dia...

Страница 6: ...and easy DIN rail mounting The impulse inputs are available on a 9 pin SUB D connector male The outputs are available on a 9 pin SUB D connector female For power supply of the unit and of encoders tw...

Страница 7: ...0 mA at pin 4 of the input connector SUB D 9 male can be made available This voltage can also be taken from the screw terminal marked 5V For use of the 5 V auxiliary voltage at the input connector or...

Страница 8: ...by phase displacement quadrature pulses 90 A B forward 90 A B reverse 1 2 3 4 5 6 7 8 ON OFF VCC GND DIL Switch 1 3 5 ON 2 4 6 OFF 5 2 Indication of direction by static direction output A B B Low forw...

Страница 9: ...pins 4 and 5 Connect the screen to the supply minus wire at the PU204 side pin 5 6 2 Where you use an encoder with separate supply or the encoder simulation of a drive Set DIL switch 7 to OFF 8 to ON...

Страница 10: ...TTL RS422 A A B B Z Z max 200 kHz male SUB D connector 9 pin Inkremental output Levels Output logic Channels Output current Signal delay time Connections 5 V TTL RS 422 push pull A B Z max 30 mA per c...