3.3.

 

Optical Connections 

 
For connection of the modules a cord set of multimode optical fiber cables assembled by 
motrona can be used. Alternatively any multimode optical fiber cable 50/125 µm or 62.5/125 
µm will be suitable. 
 

 

Single-mode optical fiber cables cannot be used. 

 
Please keep the dust protection covers of the optical transmitters and receivers, and put them 
back in place when no optical fiber cable is connected to the modules, in order to avoid any 
soiling by dust or any other substance. 
 

 

 
Make sure here that the connector of the optical fiber cable is correctly in place 
and that the bayonets catch is locked. 
 
It must also be noted that the ST connector in use is indexed and has an 
orientation spigot which must engage the slots of the optical emitter and of the 
optical receiver. Please never force! 
 

 
 

4.

 

LED Function 

 
The green control LED of the transmitter must be on when the modules are connected correctly 
by means of a proper cable. The green LED of the receiver must also be on. 
 
If the LED of the module is not on, make sure that the supply voltage is applied and that it is 
connected with the right polarity. 
 
If the LED of the receiver module blinks, the optical fiber cable is not connected or broken. 

Содержание LW213

Страница 1: ...able can be routed through explosive areas as well Input Output data rate of max 2 Mbit s transmitter and receiver Resistant against extremely strong electromagnetic fields Already assembled optical f...

Страница 2: ...nical Specifications updatet Legal notices All contents included in this manual are protected by the terms of use and copyrights of motrona GmbH Any reproduction modification usage or publication in o...

Страница 3: ...the right to modify the hardware software or operation manual at any time and without prior notice Therefore there might be minor differences between the unit and the descriptions in operation manual...

Страница 4: ...oss sections for wiring are described in the Technical Specifications chapter Before first start up it must be ensured that all connections and wires are firmly seated and secured in the screw termina...

Страница 5: ...ents with strong electromagnetic interference or when a potential separation is necessary due to high ground potential differences between signal source and signal processing equipment High ground pot...

Страница 6: ...l D 10 Channel D 11 Cable shield connector With dual channel transmitter versions necessarily all inverted tracks must be connected Unconnected inverted tracks inevitably lead to malfunctions If the e...

Страница 7: ...must be 2 kohms If there are no specific requirements for the output signals of the receiver modules e g low transmission frequencies in the lower kHz range the outputs may be operated as single pole...

Страница 8: ...bstance Make sure here that the connector of the optical fiber cable is correctly in place and that the bayonets catch is locked It must also be noted that the ST connector in use is indexed and has a...

Страница 9: ...Lw215_01g_oi_e doc Apr 16 Page 9 10 5 Dimensions 75 0 19 0 21 7 19 0 73 5 92 3 110 8 75 0 mm 2 953 19 0 mm 0 748 92 3 mm 3 634 21 7 mm 0 854 110 8 mm 4 362 73 5 mm 2 894 19 0 mm 0 748...

Страница 10: ...e underside of the housing Electrical in and outputs Number of channels Tracks Signal levels Data rate input output 4 independent channels A B C D A A B B C C D D resp A B C D with single track versio...

Отзывы: