1.3

 

Installation 

The device is only allowed to be installed and operated within the permissible temperature 
range. Please ensure an adequate ventilation and avoid all direct contact between the device 
and hot or aggressive gases and liquids.  

 

Before installation or maintenance, the unit must be disconnected from all voltage-sources. 
Further it must be ensured that no danger can arise by touching the disconnected voltage-
sources. 

 

Devices which are supplied by AC-voltages, must be connected exclusively by switches, 
respectively circuit-breakers with the low voltage network. The switch or circuit-breaker must 
be placed as near as possible to the device and further indicated as separator. 

 

Incoming as well as outgoing wires and wires for extra low voltages (ELV) must be separated 
from dangerous electrical cables (SELV circuits) by using a double resp. increased isolation. 

 

All selected wires and isolations must be conform to the provided voltage- and temperature-
ranges. Further all country- and application-specific standards, which are relevant for structure, 
form and quality of the wires, must be ensured. Indications about the permissible wire cross-
sections for wiring are described in the “Technical Specifications” chapter.  

 

Before first start-up it must be ensured that all connections and wires are firmly seated and 
secured in the screw terminals. All (inclusively unused) terminals must be fastened by turning 
the relevant screws clockwise up to the stop.  

 

Overvoltages at the connections must be limited to values in accordance to the overvoltage 
category II.  

 

For placement, wiring, environmental conditions as well as shielding and earthing/grounding of 
the supply lines the general standards of industrial automation industry and the specific 
shielding instructions of the manufacturer are valid. Please find all respective hints and rules on  

www.motrona.com/download.html

 --> “[General EMC Rules for Wiring, Screening and 

Earthing]”. 
 

1.4

 

Cleaning, Maintenance and Service Notes 

To clean the front of the unit please use only a slightly damp (not wet!), soft cloth. For the rear 
no cleaning is necessary. For an unscheduled, individual cleaning of the rear the maintenance 
staff or assembler is self-responsible.  

 

During normal operation no maintenance is necessary. In case of unexpected problems, failures 
or malfunctions the device must be shipped for back to the manufacturer for checking, 
adjustment and reparation (if necessary). Unauthorized opening and repairing can have 
negative effects or failures to the protection-measures of the unit.   
 

Содержание LW213

Страница 1: ...able can be routed through explosive areas as well Input Output data rate of max 2 Mbit s transmitter and receiver Resistant against extremely strong electromagnetic fields Already assembled optical f...

Страница 2: ...nical Specifications updatet Legal notices All contents included in this manual are protected by the terms of use and copyrights of motrona GmbH Any reproduction modification usage or publication in o...

Страница 3: ...the right to modify the hardware software or operation manual at any time and without prior notice Therefore there might be minor differences between the unit and the descriptions in operation manual...

Страница 4: ...oss sections for wiring are described in the Technical Specifications chapter Before first start up it must be ensured that all connections and wires are firmly seated and secured in the screw termina...

Страница 5: ...ents with strong electromagnetic interference or when a potential separation is necessary due to high ground potential differences between signal source and signal processing equipment High ground pot...

Страница 6: ...l D 10 Channel D 11 Cable shield connector With dual channel transmitter versions necessarily all inverted tracks must be connected Unconnected inverted tracks inevitably lead to malfunctions If the e...

Страница 7: ...must be 2 kohms If there are no specific requirements for the output signals of the receiver modules e g low transmission frequencies in the lower kHz range the outputs may be operated as single pole...

Страница 8: ...bstance Make sure here that the connector of the optical fiber cable is correctly in place and that the bayonets catch is locked It must also be noted that the ST connector in use is indexed and has a...

Страница 9: ...Lw215_01g_oi_e doc Apr 16 Page 9 10 5 Dimensions 75 0 19 0 21 7 19 0 73 5 92 3 110 8 75 0 mm 2 953 19 0 mm 0 748 92 3 mm 3 634 21 7 mm 0 854 110 8 mm 4 362 73 5 mm 2 894 19 0 mm 0 748...

Страница 10: ...e underside of the housing Electrical in and outputs Number of channels Tracks Signal levels Data rate input output 4 independent channels A B C D A A B B C C D D resp A B C D with single track versio...

Отзывы: