![Motrona IT251 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/motrona/it251/it251_operating-manual_1839559008.webp)
It251_02c_oi_e.doc / Apr-16
Page 8 / 16
5.
Basic Switch Settings
Upon commissioning, some basic settings must be done by switch DIL4.
These settings select one of the possible standards for expressing the direction of rotation on
inputs and outputs. Also the potential of the metallic housings of the SUB-D-connectors can be
set, and the inputs can be enabled or disabled (RS422 signals or HTL signals)
Changes of the DIL switch positions will become active
only after the next power-up of the unit!
DIL 3
DIL 4
Front side
Back side
Top side
DIL switches DIL3 and DIL4 are located on the top side and switches DIL1 and DIL2 are located on
the bottom side of the unit.